F2

1. Fault-finding

Problem

Component

Possible cause

Remedy

By whom?

System
does not
start up

Control
circuitry

No voltage supply to

system or control
circuitry

Check mains voltage

Electrician

Control
circuitry

Fault on

– motor contactor
– fuses

Check

Electrician

Control
circuitry

Bimetal relay has

switched off

Wait for motor to cool down, and
then re-set relay.

Measure motor current. If

current consumption is too high,

relieve tension on piston seal
(see Maintenance Tasks).

Electrician

Pressure

switch

(Accessory
kit)

Defective or wrongly

adjusted pressure switch

Release pressure from system,

and check pressure valve.

Customer
service

System
does not
build up
pressure

V-belt

No tension in V-belt

Tighten V-belt (see Maintenance
Tasks)

Operator

Filter or

strainer

(Accessories)

Blocked filter or strainer
in supply line

Remove and clean filter or

strainer.

Operator

Inlet hose

Supply volume too small

Test whether the correct amount

of cleaning liquid is being
supplied to system.

Operator

High-pressure
pump

Worn out valves or

broken valve spring

Replace defective part.

Operator

High-pressure
pump

Defective piston, seal or

valve

Replace defective part.

Customer
service

Detergent
reservoir
(Accessory
kit)

Pump taking in air due

to empty detergent
container

Fill detergent reservoir.

Operator

Screech-
ing noise

V-belt

Incorrect V-belt tension

Tighten V-belt (see Maintenance
Tasks).

Operator