beautypg.com

E. care and maintenance, Maintenance schedule – Karcher SHD-R 3000 User Manual

Page 19

background image

English

SHD-R 3000

5.956-486 A2005937 (06/03)

E3

E. Care and maintenance

2. Maintenance schedule

Frequency

Type of pump

SHD-R 3000
(F)

Action

Procedure

By whom?

Monthly

or after
every 160
operating

hours

Standard
S / SVA

Check pump for leaks

If during operation more than

5 droplets per minute leak from
the pump, tighten piston seal

Operator

Standard
S

Lubrication

Lubricate with 2 pump strokes of

grease gun per nipple

Operator

After
every 200
operating

hours

LM

Oil change

See Maintenance Tasks

Operator

Six-monthly
or after
every 500
operating
hours

Standard
S / SVA
SLA
SSR

Oil change

See Maintenance Tasks

Operator

After
every 1000
operating

hours

all

– Check and clean valves on pump
– Check piston
– Replace set of seals if required
– Oil change
– Check for correct functioning

Customer
service

Annually

all

Check tension of V-belt

See Maintenance Tasks

Operator

all

Formal test

Inspection in accordance with
Directive on "Working With
Liquid-spraying Devices"

Specialist