E. Care and maintenance

2. Maintenance schedule

Frequency

Type of pump

SHD-R 3000
(F)

Action

Procedure

By whom?

1, 2, 4, 10

hours after
initial start-
up.

LM
SLA
SSR

Regulate tension in

compression glands

See Maintenance Tasks

Operator

Once
only after
first 100
operating
hours

all

Check tension
of V-belt

See Maintenance Tasks

Operator

all

Oil change

See Maintenance Tasks

Operator

Weekly
or after
every 40
operating

hours

all

Check oil level

Oil level must be between MIN
and MAX marks. If level below

MIN, fill up with oil.

Operator

Standard
S / SVA
SLA
SSR

Check oil condition

If oil is milky-white, change oil

and tighten piston seal (See

Maintenance Tasks)

Operator

LM

Check oil condition

If oil has thinned out or is

discoloured, change oil and
tighten piston seal (See

Maintenance Tasks)

Operator

all

Check high-pressure
hoses

Visual check of high-pressure

hoses for signs of damage such

as

– wear due to abrasion
– inner fabric is visible
– creases due to bending
– porous and split rubber

Replace any damaged hoses

Operator