beautypg.com

Connecting the ird ground wire, Multiple multiswitch installation, 28 tracvision g4 technical manual – KVH Industries TracVision G4 User Manual

Page 33

background image

Multiple Multiswitch Installation

If you need to connect more than four IRDs to the TracVision
antenna, you may carry out a multiple multiswitch installation,
as shown in Figure 2-19.

Connecting the IRD Ground Wire

A grounding wire has been provided to connect your IRD to a
suitable ground. Attach the grounding wire to any suitable screw
on the rear panel of the IRD with a good contact with the IRD
chassis. The other end should be connected to a suitable ground,
ideally to the ADCU ground terminal (route the ground wire to the
ADCU and leave unconnected for now)
. Each IRD that you connect
to the TracVision system should have a similar ground
connection.

If you are using a multiswitch, you can ground the multiswitch instead
of the individual IRDs.

54-0147

28

TracVision G4 Technical Manual

Multiswitch

DC In

RHCP

+13v

VHF/UHF

LHCP

+18v

Out 1

Out 2

Out 3

Out 4

DC Power

Multiswitch

DC In

RHCP

+13v

VHF/UHF

LHCP

+18v

Out 1

Out 2

Out 3

Out 4

DC Power

IRD #5

IRD #6

IRD #8

IRD #7

RF Splitters/

Power Dividers

IRD #2

IRD #3

IRD #4

IRD #1

TracVision Antenna Baseplate

RF1

RF2

Data

Power

Figure 2-19

Multiple Multiswitch Installation

(North American systems only)

Be sure to connect a ground cable
from each IRD to a suitable ground,