Replacing a European LNB

1. Using a

7

16

" wrench, carefully disconnect the RF

connectors from the LNB.

2. Note the currently set skew value, as indicated by

the stickers on the LNB and choke assembly (see
Figure 5-11).

3. Loosen the wing screws and remove the LNB from

the choke assembly as shown in Figure 5-12.

4. Insert the replacement LNB as far as it will go,

ensuring it reaches the bottom of the feedhorn. Be
careful not to puncture or dislodge the plastic seal
covering the LNB throat. Adjust the LNB’s
position so that it has the same skew value noted
in Step 2.

5. Apply a small amount of thread-locking

compound (e.g., Loctite 425 or equivalent) to the
wing screw threads and tighten the screws to
secure the LNB in position.

6. Reattach the RF connectors to the LNB.

54-0147

116

TracVision G4 Technical Manual

Figure 5-12

European LNB Removal

Figure 5-11

Skew Angle Labels