Page 10
21
WARNING:
Before pulling out the lamp module, switch off the projector and unplug the mains
lead first!
For lamp replacement let the module cool down before touching the lamp and the
surrounding area. Do not place the hot lampmodule on heat sensitive surfaces.
Glass may shatter. Wear gloves. Keep glass covered.
Do not touch the small bulb or the mirror surface! If you accidentally get finger
prints on them, remove marks with a soft cloth moistened with rubbing alcohol.
Replacement of a defective lamp is very easy with your EKTAPRO Slide Projector:
Replacement of a defective lamp
3.
Push the ejector lever completely to
the side.
The defective lamp will come free of its
holder.
4.
Remove the defective lamp and in-
sert the new lamp.
.
Push the ejector lever back to the right
and press down until it locks into its hold-
ing.
.
Push the lamp module back into the
projector until it locks.
1.
2.
3.
4.
1.
Press down and hold down the
lamp module release (8) and...
2.
... pull out the lamp module (6).
.
Push the lamp ejector lever down
so that it clears the retaining clip.
Note:
For your projection requirements you
have a choice of 3 lamps with different
brightness and lamp life (see Accesso-
ries page 22).
Kodak gives you a one year guarantee on
the original projector (without accessories
and lamp) provided the projectors have
been serviced regularly.
Cleaning the projector
WARNING:
For safety, always turn the machine
off, unplug the mains lead and allow
the projector to cool down before
cleaning.
Housing:
Wipe the housing with a soft, cotton cloth
and use a cleaner designed for plastic ma-
terials. Do not use solvents or spirit based
cleaners.
Optics:
Do not touch optical surfaces!
Clean the lens with a soft lintfree cloth or
with special lens tissues.
Never wipe over a dry surface!
Use a special lens cleaner (available from
photographic dealers) or add moisture by
breathing over the parts to be cleaned.
Guarantee