3.4 Making Trunk Connections

Two switch units can be cascaded together through any regular switched

data port on each unit when a port expansion is required. However, the

transfer bandwidth between the two cascaded ports is limited to 200Mbps

full duplex. To increase the bandwidth for the connection between two

switch units, a trunking function is implemented on the switch unit for

this purpose. Normal data ports can be configured optionally as trunking

ports through the network management operation.

Two or more trunking ports composes one trunk. Two switch units can

be cascaded through one trunk. The aggregated bandwidth of one trunk

can be up to 1.6Gbps, if 8 trunking ports are used for one trunk.

Refer to the software operation manuals in the supplied CD-ROM for

more information about how to configure a data port as a trunking port.

The following figure illustrates an example of 4-port trunk connection

between switch A and switch B. The Port 3, 4, 5 and 6 of switch A are

configured as trunking ports and compose one trunk. The Port 5, 6, 7, and

8 of switch B are configured as trunking ports and compose one trunk.