79 appendix – Kenwood TS-570S TS-570D User Manual
Page 85
![background image](/manuals/157920/85/background.png)
79
APPENDIX
●
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Sets or reads transmit power.
PC
POWER CONTROL
P1
47
POWER
CONTROL
P
C
P1
;
P
C
;
P1
P
C
;
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Sets Speech Processor OFF/ON or reads status.
PR
SPEECH PROCESSOR
P1
1
SPEECH
PROCESSOR
OFF/ON
P
R P1
P
R P1 ;
P
R
;
;
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Sets Power OFF/ON or reads status.
PS
POWER SWITCH
P1
1
POWER
OFF/ON
P
S P1
P
S P1 ;
P
S
;
;
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Sets or reads CW RX pitch.
PT
CW RX PITCH
P1
52
CW RX PITCH
P
T
P1
P
T
P
T
;
;
P1
;
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Sets or reads RF ATT(attenuator).
RA
RF ATTENUATOR
P1
–
ATTENUATOR
R A
R A
;
P1
R A
;
P1
;
00: OFF
01: ON
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Lowers/raises RIT frequency.
RD
R
;
RIT DOWN/UP
D/U
Note:
This command also affects the XIT
frequency (same as RIT shift).
The command functions
independently from the RIT/XIT
control.
RU
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Sets RIT OFF/ON or reads status.
RT
RIT
P1
1
RIT OFF/ON
R T P1
R T P1 ;
R T
;
;
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Sets the RIT frequency shift to 0.
RC
R
;
RIT CLEAR
C
Note:
This command also clears the XIT
frequency (same as RIT shift).
The command functions
independently from the RIT/XIT
control.
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Selects a meter function or reads meter values.
RM
READ METER
P1
24
METER SWITCH
R M P1
;
R M
;
P1
R
M
;
P2
P2
22
METER VALUE
Parameter Format Parameter function
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6 7
8
9 10 11 12 13 14
1
2
3
4
5
6 7
8
9 10 11 12 13 14
Sets or reads RF gain.
RG
RF GAIN
P1
31
RF GAIN
R G
P1
R G
P1
R G
;
;
;