beautypg.com

79 appendix – Kenwood TS-570S TS-570D User Manual

Page 85

background image

79

APPENDIX

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Sets or reads transmit power.

PC

POWER CONTROL

P1

47

POWER
CONTROL

P

C

P1

;

P

C

;

P1

P

C

;

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Sets Speech Processor OFF/ON or reads status.

PR

SPEECH PROCESSOR

P1

1

SPEECH
PROCESSOR
OFF/ON

P

R P1

P

R P1 ;

P

R

;

;

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Sets Power OFF/ON or reads status.

PS

POWER SWITCH

P1

1

POWER
OFF/ON

P

S P1

P

S P1 ;

P

S

;

;

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Sets or reads CW RX pitch.

PT

CW RX PITCH

P1

52

CW RX PITCH

P

T

P1

P

T

P

T

;

;

P1

;

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Sets or reads RF ATT(attenuator).

RA

RF ATTENUATOR

P1

ATTENUATOR

R A

R A

;

P1

R A

;

P1

;

00: OFF
01: ON

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Lowers/raises RIT frequency.

RD

R

;

RIT DOWN/UP

D/U

Note:
This command also affects the XIT
frequency (same as RIT shift).
The command functions
independently from the RIT/XIT
control.

RU

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Sets RIT OFF/ON or reads status.

RT

RIT

P1

1

RIT OFF/ON

R T P1

R T P1 ;

R T

;

;

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Sets the RIT frequency shift to 0.

RC

R

;

RIT CLEAR

C

Note:
This command also clears the XIT
frequency (same as RIT shift).
The command functions
independently from the RIT/XIT
control.

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Selects a meter function or reads meter values.

RM

READ METER

P1

24

METER SWITCH

R M P1

;

R M

;

P1

R

M

;

P2

P2

22

METER VALUE

Parameter Format Parameter function

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6 7

8

9 10 11 12 13 14

1

2

3

4

5

6 7

8

9 10 11 12 13 14

Sets or reads RF gain.

RG

RF GAIN

P1

31

RF GAIN

R G

P1

R G

P1

R G

;

;

;