Channel Trigger
Trigger modes and appendant registers
Channel window trigger for short inner signals
The analog input is continuously sampled with the selected
sample rate. The upper and the lower levels define a win-
dow. Every time the signal enters the window from the out-
side, the pulsewidth counter is startet. If the pulsewidth
counter stops and the signal is still inside the window, no
trigger will be detected.
If the signal leaves the window before the pulsewidth coun-
ter has stopped, the triggerevent will be detected.
Channel window trigger for short outer signals
The analogd input is continuously sampled with the selected
sample rate. The upper and the lower levels define a win-
dow. Every time the signal leaves the window from the insi-
de, the pulsewidth counter is startet. If the pulsewidth
counter stops and the signal is still outside the window, no
trigger will be detected.
If the signal enters the window before the pulsewidth coun-
ter has stopped, the triggerevent will be detected.
Register
Value
Direction
set to
Value
SPC_TRIGGERMODE
40000
r/w
TM_CHANNEL
20040
SPC_TRIGGERMODE0
40200
r/w
TM_CHXWINENTER_SP
10042
SPC_HIGHLEVEL0
42000
r/w
Sets the window’s upper level relatively to the channel’s input range.
board dependant
SPC_LOWLEVEL0
42100
r/w
Sets the window’s lower level relatively to the channel’s input range.
board dependant
SPC_PULSEWIDTH
44000
r/w
Set to the desired pulsewidth in samples.
2 to 255
Register
Value
Direction
set to
Value
SPC_TRIGGERMODE
40000
r/w
TM_CHANNEL
20040
SPC_TRIGGERMODE0
40200
r/w
TM_CHXWINLEAVE_SP
10052
SPC_HIGHLEVEL0
42000
r/w
Sets the window’s upper level relatively to the channel’s input range.
board dependant
SPC_LOWLEVEL0
42100
r/w
Sets the window’s lower level relatively to the channel’s input range.
board dependant
SPC_PULSEWIDTH
44000
r/w
Set to the desired pulsewidth in samples.
2 to 255