Auto Mode Settings (AUTO MODE)

34

The Sequence mode allows you to monitor multiple preset
positions sequentially by using the sequence group containing
preset positions. You can create up to four sequence groups.

1

Create a sequence group by adding preset
positions.

The preset positions you want to monitor in the Sequence
mode should be added to the same group.

2

Use the joystick lever (xy) to select [SEQUENCE],
use the lever (vw) to select a group (A to D) to
monitor in the Sequence mode, and press the
[ENTER] button.

The SEQUENCE screen appears.

3

To review the surveillance locations, use the
joystick lever (xy) to select [EDIT] – “SET y”, and
press the [ENTER] button.

The preset map screen appears.

Confirm the sequence group indication for each preset
number, and edit the group if necessary.

Use the joystick lever (xy) to select [MENU], and with “BACK”
displayed, press the [ENTER] button. The SEQUENCE screen
in step 2 above appears again.

4

Use the joystick lever (xy) to select [ORDER] and
use the lever (vw) to select the sequence option.

Available settings:

• STEP:

Monitors the preset positions in the order of
their numbers.

• RANDOM: Monitors the preset positions in the sequence

group randomly.

5

Use the joystick lever (xy) to select [PAUSE TIME]
and use the lever (vw) to select the duration for
which the camera pauses at each preset position.

Available settings: 3S, 4S, 5S, 6S, 7S, 8S, 9S, 10S, 15S,

20S, 30S, 45S, 1M, PRE
(S: Second, M: Minute)

6

Use the joystick lever (xy) to select [SEQ SPEED]
and use the lever (vw) to select the speed in which
the camera moves between individual preset
positions.

Available settings: 1 (slow) - 15 (fast)

7

Use the joystick lever (xy) to select [RUN] – “SET
y

”, and press the [ENTER] button.

The on-screen menu disappears, and the Sequence mode
operation starts.

Pressing the [ENTER] button stops the operation.

Memo: While monitoring in the normal screen, the Auto mode is

turned on or off in the main screen of the system controller.
For details, refer to the system controller instruction manual.

A

Monitoring multiple preset positions
sequentially (SEQUENCE)

AUTO MODE

SEQUENCE

y

AUTO PAN

y

TOUR

y

AUTO RETURN
TIME

PRESET
MENU

A
1
1
SEQ A
1M

OFF
BACK

SEQUENCE A

EDIT

y

ORDER
PAUSE TIME

[SEQ SPEED]

8

RUN

y


MENU

SET
STEP
5S

SET

BACK

PRESET NO.SELECT

1:A 11:- 21:- 31:-
2:- 12:- 22:- 32:-
3:- 13:- 23:- 33:-
4:- 14:- 24:- 34:-
5:- 15:- 25:- 35:-
6:- 16:- 26:- 36:-
7:- 17:- 27:- 37:-
8:- 18:- 28:- 38:-
9:- 19:- 29:- 39:-
10:- 20:- 30:- 40:-
MENU

BACK

When selecting “PRE”, the pause duration set in the
[PAUSE TIME] setting for each preset position is applied.

y

8

y

SEQUENCE A

EDIT
ORDER
PAUSE TIME

[SEQ SPEED]

RUN

MENU

SET
STEP
5S

SET

BACK