For Machines Mfg. Since 8/09

Model SB1020

S E R V I C E

V1

U1

W1

1

7

9

3

6

5

4

2

8

Figure 52. Saw motor rewired for 220V.

9. Re-install the pump motor junction box

cover, then remove the saw motor junction

box cover.

10. Remove wires 4, 5, and 6 from the terminal

block posts and remove the three pre-

installed jumpers. The jumpers will not be

needed for 220V configuration (see Page 44).

11. Remove wires 7, 8, and 9 from the lower

terminal block posts.

12. Remove the two screws securing the

terminal block to the motor housing.

13. Pair wires 4 and 7, 5 and 8, and 6 and 9. Re-

attach these wire pairs to the terminal block

as shown in Figure 52.

14. Reposition the terminal block into its

original position and secure it in place with

the screws removed in Step 12.

15.

Replace the saw motor junction cover and

tighten the screws.

16. Remove the NEMA 5-15 plug from the power

cord and attach a NEMA 6-15 plug per the

manufacturer’s instructions.