220v conversion, Pre-wired for 110v, Rewired for 220v – Southbend SB1020 User Manual

Page 43

background image

For Machines Mfg. Since 8/09

Model SB1020

-41-

S E R V I C E

Wiring diagrams are provided in this section

showing the Model SB1020 wired for both 110V

and 220V. Refer to these diagrams if needed

when following this procedure. Additionally, you

must purchase a 220V electrical box cooling fan

in order to complete the conversion.

items Needed

Qty.

220V Electrical Box Cooling Fan

(Part No. PSB1020511)* ................................1

Phillips Screwdriver #2 ........................................1

NEMA 6-15 Plug ...................................................1

*Contact South Bend Customer Service at (360)

734-1540 to order this part.

To convert the Model SB1020 to 220V:

1. DISCONNECT BANDSAW FROM POWER!

2. Open the upper electrical box, then locate

the jumper wire at the J1 location on the

circuit board.

3. Carefully switch the jumper wire from the

115V position to the 230V position (see

Figure 49).

220V Conversion

Figure 49. Changing jumper wire at location J1.

U

V

W

L1

L2

Jumper Moved

for 220V

115V

P1

P3 P2

V1

W1

L1

L2

U1

G | 0 | 110 | 220 | 0 | 24

Transformer

LCE TBSM 20VA

P1

P2

P3

230V

115V

230V

J1

J1

4. Locate the transformer in the electrical box.

5. Depress the push spring terminal at the 110

terminal Position A and remove the L2 wire

(see Figure 50).

Transformer

LCE TBSM 20VA

6

L1

0

L2

position A

position B

Figure 50. Transformer rewired for 220V.

6. Depress the 220 terminal push spring

terminal at Postion B and insert the L2 wire.

7. Replace the 115V cooling fan with the

220V electrical box cooling fan (Part No.

PSB1020511).

8. Remove the pump motor junction box cover,

then re-configure the pump motor jumpers

as shown in Figure 51.

Figure 51. pump motor rewired for 220V.

V2

V2

U2

U2

4

1

3

2

S. Capacitor

3M

F

D 45

0V

A

C

GND

PRE-WIRED

FOR 110V

V2

V2

U2

U2

4

1

3

2

S. Capacitor

3M

F

D 45

0V

A

C

GND

REWIRED

FOR 220V

Note jumper locations