beautypg.com

Schumacher SP3 User Manual

Page 12

background image

• 12 •

NOTE: If the charger has to provide its maximum maintain current

for a continuous 12 hour period, it will go into Abort Mode (see

Aborted Charge section). This is usually caused by a drain on the

battery, or the battery could be bad. Make sure there are no loads

on the battery. If there are, remove them. If there are none, have the

battery checked or replaced.

Maintaining a Battery

The SP3 is a battery charger/maintainer that maintains both 6 and

12 volt batteries, keeping them at full charge. It can charge small

batteries and maintain both small and large batteries. If you are

maintaining a fully charged large battery, you are properly utilizing

the battery charger. However, if you were to use this battery charger

to charge a large battery, such as a marine deep cycle battery, that

was not fully charged, you may lose some of the battery’s capacity.

This would cause the large battery to be unable to hold a charge

and become useless.

Therefore, we do not recommend charging

a large battery with this unit.

NOTE: The maintain mode technology utilized in Schumacher

chargers allows you to safely charge and maintain a healthy

battery for extended periods of time. However, problems with the

battery, electrical problems in the vehicle, improper connections

or other unanticipated conditions could cause excessive current

draws. As such, occasionally monitoring your battery and the

charging process is recommended.

Desulfation Mode

If the battery is left discharged for an extended period of time,

it could become sulfated and not accept a normal charge. If the

charger detects a sulfated battery, the charger will switch to a

special mode of operation designed for such batteries. If successful,

normal charging will resume after the battery is desulfated.

Desulfation could take up to 8 hours. If desulfation fails, charging

will abort, the yellow LED will blink, and the display will show

“CHARGING ABORTED BAD BATTERY”.

Aborted Charge

If charging cannot be completed normally, charging will abort.

When charging aborts, the charger’s output is shut off, the yellow

LED will blink, and the display will show “CHARGING ABORTED

BAD BATTERY”. To reset after an aborted charge, unplug the

charger from the outlet, wait a few moments and plug it back in.