beautypg.com

Superior DT-400CMP User Manual

Page 22

background image

22

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Figure 52

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the optional
remote wall switch and turn the gas control
switch to the “ON” position. Ensure the ignitor
lights the pilot. The pilot flame should engulf
the flame rod as shown in

Figure 52.

ELECTRONIC

Proper Flame

Adjustment

Pilot
Nozzle

3/8 To 1/2 Inch

(9 mm to 13 mm)

Ground
Electrode

Flame Rod

Hot Surface

Igniter

Latch

Latch

Glass Door

Firebox Floor

Bottom Vee-flange

Door Frame

Top Flange
Door Frame

Figure 53 - INSTALLING THE GLASS DOOR

Figure 49

Step 7. INSTALLING LOGS AND GLOWING
EMBERS

The logs are packaged in a carton which is
shrink-wrapped to the front glass enclosure
panel. The glowing embers are packaged sepa-
rately in a plastic bag located in the control area
of the fireplace.

WARNING: HANDLE THIS GLASS WITH
EXTREME CARE! THE GLASS PANEL IS
SUSCEPTIBLE TO DAMAGE — DO NOT
SCRATCH WHILE HANDLING OR WHILE
RE-INSTALLING THE GLASS DOOR FRAME.

WARNING: NEVER OPERATE THE APPLI-
ANCE WITHOUT THE FRONT GLASS EN-
CLOSURE PANEL IN PLACE AND SECURE.

Step 9. INSTALLING THE GLASS DOOR

Retrieve the glass door. Visually inspect the
gasket on the backside of the frame. Gasket
surface must be clean, free of irregularities and
seated firmly.

Position the door in front of the firebox opening
with the bottom of the door held away from the
fireplace

(Figure 53 ). Hook the top flange of

the door frame over the top of the firebox frame.

Let the bottom of the door frame swing gently
in towards the fireplace ensuring that the gas-
ket seats evenly as the door frame draws shut.
Fasten the two latches located underneath the
firebox floor to the door's vee-flange. Close
both the latches securely.

Refer to the homeowner's care and operation
instructions for detailed placement instruc-
tions for the logs and glowing embers.

Sit and Honeywell Millivolt Gas Valve

Showing Piezo Ignitor Location (Each Unit is

Equipped with Only One of these Gas Valves)

Piezo

Ignitor

SIT Gas Valve

Honeywell
Gas Valve

Step 8. CHECKING APPLIANCE OPERATION

With gas line installed run initial system checkout
before closing up the front of the unit. Follow the
pilot lighting instructions provided in the
Homeowner's Care and Operation Instructions.
For piezo ignitor location see

Figure 49 (SIT and

Honeywell millivolt appliances only).

Note: Instructions are also found on the litera-
ture tag attached to the gas valve train.

When first lighting the appliance, it will take a few
minutes for the line to purge itself of air. Once
purging is complete, the pilot and burner will light
and operate as indicated in the instruction manual.
Subsequent lightings of the appliance will not
require such purging. Inspect the pilot flame
(remove logs, if necessary, handling carefully).

SIT and Honeywell Millivolt Appliance Checkout

The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge. The top

³⁄₈"

(10 mm) at the pilot generator (thermopile)
and the top

¹⁄₈" min (tip) of the quick drop out

thermocouple should be engulfed in the pilot
flame. The flame should project 1" (25 mm)
beyond the hood at all three ports (

Figure 50

- SIT, Figure 51 - Honeywell )

Replace logs if removed for pilot inspection.

To light the burner; turn “ON” the remote wall
switch and rotate the gas valve control knob
counterclockwise to the “ON” position.

Figure 50

Figure 51

¹⁄₈" Min

(3 mm)

Thermocouple

Ignitor Rod

Hood

³⁄₈" Min

(9 mm)

Thermopile

HONEYWELL MILLIVOLT

Pilot

Nozzels

SIT MILLIVOLT

Thermocouple

Hood

Ignitor Rod

³⁄₈" Min

(9 mm)

Thermopile

Pilot
Nozzels

This manual is related to the following products: