Power.supply, Circuit.requirements, Notice – Woodstock SHOP FOX W1706 User Manual
Page 9

-7-
Model W1706 (Mfg. Since 3/13)
EL
EC
TR
IC
A
L
POWER.SUPPLY
The.machine.must.be.properly.set.up.
before.it.is.safe.to.operate..DO.NOT.
connect.this.machine.to.the.power.
source.until.instructed.to.do.so.in.the.
"Test.Run".portion.of.this.manual.
DO.NOT.work.on.your.electrical.system.
if.you.are.unsure.about.electrical.codes.
and. wiring!. Seek. assistance. from. a.
qualified. electrician.. Ignoring. this.
warning. can. cause. electrocution,. fire,.
or.machine.damage.
Circuit.Requirements
This machine must be connected to the correct size and
type of power supply circuit, or fire or electrical damage
may occur. Read through this section to determine if
an adequate power supply circuit is available for this
machine. If a correct circuit is not available, you must
have a qualified electrician install one before you can
operate the machine.
A power supply circuit includes all electrical equipment
between the main breaker box or fuse panel in your
building and the incoming power connections at the
machine. The power supply circuit used for this machine
must be sized to safely handle the full-load current drawn
from the machine for an extended period of time.
Circuit.Requirements.for.110V.(Prewired)
This machine is prewired to operate on a 110V power
supply circuit that has a verified ground and meets the
following requirements:
Circuit.Type................ 110V/120V,.60.Hz,.Single-Phase
Circuit.Size.............................................. 15.Amps
Plug/Receptacle..................................... NEMA.5-15
Circuit.Requirements.for.220V
This machine can be converted to operate on a 220V
power supply. To do this, the motor will need to be
rewired and a new plug installed on the power cord;
refer to the
Wiring.Diagram on Page.51 for details. The
intended 220V circuit must have a verified ground and
meet the requirements that follow:
Circuit.Type................220V/240V,.60.Hz,.Single-Phase
Circuit.Size.............................................. 15.Amps
Plug/Receptacle..................................... NEMA.6-15
Full-Load.Current.Rating
The full-load current rating is the amperage a machine
draws at 100% of the rated output power. On machines
with multiple motors, this is the amperage drawn by the
largest motor or sum of all motors and electrical devices
that might operate at one time during normal operations.
Full-Load.Current.Rating.at.110V................... 11.Amps
Full-Load.Current.Rating.at.220V.................. 5.5.Amps
For. your. own. safety. and. protection.
of. property,. consult. a. qualified.
electrician. if. you. are. unsure. about.
wiring.practices.or.electrical.codes.in.
your.area.
NOTICE
The.circuit.requirements.listed.in.this.
manual. apply. to. a. dedicated. circuit—
where. only. one. machine. will. be.
running.at.a.time..If.this.machine.will.
be.connected.to.a.shared.circuit.where.
multiple. machines. will. be. running. at.
the. same. time,. consult. a. qualified.
electrician.to.ensure.that.the.circuit.is.
properly.sized.for.safe.operation.