20 plug (as recommended), Disconnect switch (as recommended), Spindle rotation and power conn- tection – Southbend SB1014 User Manual
Page 101
For Machines Mfg. Since 8/09
EVS Toolroom Lathes
-11-
E L E C T R I C A L
Spindle Rotation Switch
220V Power Connection
440V Power Connection
Fig. 10. Spindle rotation switch location.
NC
COM
NC
COM
NO
NO
7
8
6
9
Spindle Rotation Switch,
Figure 10.
spindle rotation
and power conn-
tection
Ground
Hot
Hot
Hot
15-20 PLUG
(as recommended)
L3
L2
L1
1
2
3
5
6
4
MASTER
POWER SWITCH
L3
L3
L2
L2
L1
L1
Ground
Hot
Hot
Hot
DISCONNECT
SWITCH
(as recommended)
L3
L2
L1
MASTER
POWER SWITCH
L3
L3
L2
L2
L1
L1
1
2
3
5
6
4
Inside Electrical
Box, Page 7.
Inside Electrical
Box, Page 7.
6
6
7
9
7
Spindle Rotation
Switch
To Main Junction
Block, Page 7.
6