Pipeline HD Mini Series SATA Product Manual, Rev. A

13

2.11

Acoustics

Drive emission of sound is measured consistent with the ECMA-74 and its’ referenced standards. Testing is
conducted at room temperature (approximately 25

°

C). Emission levels are reported as the total A-weighted

sound power levels for steady state, idle, and active seek modes of operation.

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and

power to operational levels.

Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this pro-
cess is the use of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to
discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone
ratios according to Annex D of the ECMA-74 standards.

*Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.

2.12

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 5:

Drive A-weighted Sound Power Levels (SWL, BA)

Idle*

CE seek

2.0 bels (typ)

2.1 bels (max)

2.1 bels (typ)

2.2 bels (max)

Table 6:

Radio frequency environments

Test

Description

Performance
level

Reference
standard

Electrostatic discharge

Contact, HCP, VCP:

± 4

kV; Air:

± 8 kV

B

EN 61000-4-2: 95

Radiated RF immunity

80 to 2,000 MHz, 10 V/m,

80% AM with 1 kHz sine

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

A

EN 61000-4-3: 96

ENV 50204: 95

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz

sine

A

EN 61000-4-6: 97

Power Frequency H-field

immunity

1 A/m, 50Hz/60Hz, 3 axes

A

EN 61000-4-8: 97

Voltage dips, interrupts

30% Reduction for 25 cycles

>95% Reduction for 250 cycles

>95%, 0.5 cycles

C

C

B

EN 61000-4-11: 94