beautypg.com

Schumacher XC103 User Manual

Page 14

background image

10

Battery Connection Indicator

If the charger does not detect a properly connected battery, the CONNECTED

LED will not light. Charging will not begin if the CONNECTED LED is

not on.
Automatic Charging Mode

When an Automatic Charge is performed, the charger switches to the Maintain

Mode (see below) automatically after the battery is charged.
Aborted Charge

If charging can not be completed normally, charging will abort. When charging

aborts, the charger’s output is shut off, all of the LEDs are turned off and the

digital display will show bad bat. In that state, the charger ignores all buttons.

To reset after an aborted charge, unplug the charger.
Desulfation Mode

If a battery is left discharged for an extended period of time, it could become

sulfated and not accept a normal charge. If the charger detects a sulfated

battery, the charger will switch to a special mode of operation designed for

such batteries. If successful, normal charging will resume after the battery is

desulfated. Desulfation could take up to 10 hours. If desulfation fails, charging

will abort and the digital display will blink.
Completion of Charge

Charge completion is indicated by the CHARGED LED . When lit, the

charger has switched to the Maintain Mode of operation.
Maintain Mode (Float-Mode Monitoring)

When the CHARGED LED is lit, the charger has started Maintain Mode.

In this mode, the charger keeps the battery fully charged by delivering a small

current when necessary. If the battery voltage drops below a preset level, the

charger will go back into Charge Mode until the battery voltage returns to the

full charge level, at which point the charger will return to Maintain Mode. The

voltage is maintained at a level determined by the BATTERY TYPE selected.
NOTE: For 12V AGM and 12V GEL CELL battery types, the CHARGED LED

might be lit before the Maintain Mode starts.

NOTE: The charger automatically switches between Charge Mode and

Maintain Mode as necessary. The CHARGED LED will cycle on when the

battery is at full charge and off when the voltage drops below a preset level

and the charger goes into Charge Mode.
Maintaining a Battery

This is a battery charger with a maintenance setting, and maintains both

6 and 12 volt batteries, keeping them at full charge. On this setting it can

charge small batteries and maintain both small and large batteries. If you

are maintaining a fully charged large battery you will be properly utilizing the

maintenance setting. However, if you were to use the maintenance setting to

charge a large battery, such as a marine deep cycle battery, that was not fully

charged you may lose some of the battery’s capacity. This would cause the

large battery to be unable to hold a charge and become useless. Therefore,

we do not recommend charging a large battery on the maintenance setting.
NOTE: The maintain mode technology utilized in Schumacher’s chargers

allows you to safely charge and maintain a healthy battery for extended

periods of time. However, problems with the battery, electrical problems in the

vehicle, improper connections or other unanticipated conditions could cause

excessive current draws. As such, occasionally monitoring your battery and the

charging process is recommended.