beautypg.com

Schumacher XC103 User Manual

Page 13

background image

9

NOTE: Once the charger has started charging the battery; if you press the

Charge Rate button once, the output current is shut off and the display with

show OFF and then the battery voltage. If you press the Charge Rate button

again, the current will go back on at the same setting it was when it was turned

off. For example: The charger is charging a battery at the slow charge rate

setting. If you press the Charge Rate button, the output is turned off. If you

press the Charge Rate button again, the output will turn back on at the slow

charge rate setting.

OPERATING INSTRUCTIONS

11.

This battery charger must be properly assembled in

accordance with the assembly instructions before it is used.
The charger does not have an ON/OFF switch. The On and Off commands are

controlled by plugging the charger into a 120V AC electrical wall outlet only

after the battery connections have been made.
Charging

Ensure that all of the charger components are in place and in good working

1.

condition, for example, the plastic boots on the battery clips.
Connect the battery following the precautions listed in sections 6 and 7.

2.

Connect the AC power following the precautions listed in section 8. Make

3.

sure to place the charger on a dry, non-flammable surface like metal or

concrete.
Select the appropriate settings for your battery.

4.

Startup Defaults: When first turned on, the charger will default to the following

startup settings:

Battery Type: Standard

Battery Voltage: 12 Volts

Charge Rate: OFF (No charge rate selected)

After 10 minutes if no buttons are pressed or no charge rate is selected, the

charger will automatically start charging at the following defaults:

Charge Current: The lowest charge rate setting available, usually 2 amps.

Charge Voltage: The lowest charge rate voltage available, usually 14.7

volts (Gel Cell), if not, then 15.4 volts (AGM), otherwise it will be 16.0 volts

(Standard battery).

Automatic Voltage Detection

When the charger is connected to a battery, it will automatically determine

whether the connected battery is a 6 volt battery or a 12 volt battery. This

eliminates the possibility of using the wrong voltage setting. The display will

show either 6 or 12 depending on what battery voltage the charger detects.
Thermal Runaway

As a safety precaution, the charger will automatically reduce the output current

if it detects the battery may be getting too hot.
NOTE: This charger is equipped with an auto-start feature. It will not supply

current to the battery clips until a battery is properly connected. Meaning, the

clips will not spark if touched together.
Battery Percent and Charge Time: This charger adjusts the charging

time in order to charge the battery completely, efficiently and safely. The

microprocessor automatically performs the necessary functions. This section

includes guidelines that can be used to estimate charging times.

This manual is related to the following products: