Speaker features, Speakers outputs power, Table 17 – Sierra Wireless WISMO218 User Manual
Page 50: Speaker details
WA_DEV_W218_PTS_002
Rev 005
Page 50 of 109
Product Technical Specification &
Customer Design Guidelines
Parameters
Min
Typ
Max
Unit
200 Hz Z2 MICN 2.2 Z2 MICN to GND 4.5 Impedance between to GND 3.2 Maximum working voltage - - mVpp Maximum rating voltage V * The input voltage depends on the input micro gain set by the AT command. Please refer to the document [2], ** Because both MICP and MICN are internally biased, it is necessary to use a coupling capacitor to connect an audio signal provided by an active generator. Only a passive microphone can be directly connected to the MICP input. Speaker Features The speaker, SPK, can either have a single-ended or a differential connection. However, it is strongly When using a single-ended connection, be sure to have a very good ground plane, very good filtering Table 17. Speaker Details Parameter Typ Unit Connection Z (SPKP, SPKN) 16 or 32 Differential mode Z (SPKP, SPKN) 8 Single-ended mode Speakers Outputs Power The maximal specifications given below are available with the maximum power output configuration
(MICP=Open)
Z2 MICP
(MICN=GND)
(MICP=GND)
Impedance between
MICP and MICN
without 2.2K
MICP and MICN with
2.2K
( MICP-MICN)
(THD 10%)
AT+VGT*=1
210
(MICP or MICN)
-0.5
-
4.4
recommended to use a differential connection in order to reject common mode noise and TDMA
noise. Moreover, in single-ended mode, half (½) of the power is lost.
as well as shielding in order to avoid any disturbance on the audio path.
values set by an AT command. The typical values are recommended.