beautypg.com

Installation / operation 5, Piping, Priming/operation – Simer Pumps PORTABLE UTILITY/SPRINKLER PUMP 2825SS User Manual

Page 5: Preparing to start the pump (refer to figure 5)

background image

For parts or assistance, call Simer Customer Service at

1-800-468-7867 / 1-800-546-7867

Installation / Operation

5

Hazardous pressure. Do not shut off the

hose or the sprinklers while the pump is running. The
hose or sprinkler head may explode.

PIPING

Both the suction and discharge ports are tapped for 1"
BSP threads. If using hoses, use hose adapters. See
Figure 2. Do not use a hose on the suction if pumping
from lakes, streams or ponds. The hose will collapse and
cause pump failure. Install a strainer with a foot valve on
the end of the suction line. Inspect and clean the strainer
frequently (Figure 4).

NOTICE: An air leak in the suction pipe may draw air in
although no water leaks out. Make sure there are no air
leaks or air pockets in the suction pipe.

PRIMING/OPERATION

NOTICE: Do not run the pump dry. Running the pump
without water can damage the impeller and may damage
the seal, causing leaking or flooding, and will void
warranty.
All suction connections must be airtight. Make sure the
suction lift is not more than 25 feet (7.6M). Fill the pump
body through the priming port before starting the pump.
Start the pump; it should pump water in under 10 min-
utes (depending on the length of the suction hose and
the height of the pump above water).

PREPARING TO START THE PUMP
(REFER TO FIGURE 5)

Risk of burns. Never run pump dry.

Running the pump without water may cause the pump to
overheat, damaging the seal and possibly causing burns
to persons handling the pump. Fill the pump with water
before starting.

Hazardous Pressure. Never run the pump

against closed discharge. To do so can boil water inside
pump, causing hazardous pressure in unit, risk of explo-
sion and possibly scalding persons handling pump.
1. Remove the priming plug from the priming tee and

fill the pump. Fill all piping between the pump and
the well and make sure that all piping in the well is
full. If you have also installed a priming tee in the
suction piping, remove the plug from the tee and fill
the suction piping. See Figure 5.

Water Faucet

Connect the Pump Inlet
to the Water Faucet
for use with Sprinklers.

3942 0401

Hose
Adapters

Figure 3: Connect pump to a spigot for use with sprin-
klers. Connect with adapters supplied with pump

115V, GFCI
Protected,
Grounded
Outlet Box

Discharge Line
(Garden Hose or
Rigid Pipe)

Suction Line
(Garden Hose or
Rigid Pipe)

Foot valve with
strainer (clean
frequently)

Hose
Adapters

Figure 4: Strainer and foot valve installation

Remove the
plug and
fill the pump
and the piping
through the
priming tee.

Figure 5: Prime the Pump