beautypg.com

General – Sanyo C3682 User Manual

Page 76

background image

3

1. General

This booklet briefly outlines where and how to install the

air conditioning system. Please read over the entire set

of instructions for the indoor and outdoor units and make

sure all accessory parts listed are with the system before

beginning.

1-1. Tools Required for Installation (not supplied)

1. Standard screwdriver

2. Phillips head screwdriver

3. Knife or wire stripper

4. Tape measure

5. Carpenter’s level

6. Sabre saw or key hole saw

7. Hacksaw

8. Core bits

9. Hammer

10. Drill

11. Tube cutter

12. Tube flaring tool

13. Torque wrench

14. Adjustable wrench

15. Reamer (for deburring)

1-2. Accessories Supplied with Unit

Table 1

1-3. Optional Copper Tubing Kit

Copper tubing for connecting the outdoor unit to the

indoor unit is available in kits which contain the narrow

and wide tubing, fittings and insulation. Consult your

nearest sales outlet or air conditioning workshop.

1-4. Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately from

a local source, you will need:

1.

Deoxidized annealed copper tube for refrigerant tub-

ing as detailed in Table 2.

Cut each tube to the appropriate lengths 1' to 1'4"

(30 cm to 40 cm) to dampen vibration between units.

Table 2

2.

Foamed polyethylene insulation for the specified

copper tubes as required to precise length of tubing.

Wall thickness of the insulation should be not less

than 5/16" (8 mm).

3.

Use insulated copper wire for field wiring. Wire size

varies with the total length of wiring. Refer to 3-6.

Wiring Instructions for details.

Parts

Figure

Q’ty

Parts

Figure

Q’ty

1

1

Tapping screw

Rawl plug

Truss-head
Phillips

5

/

32

Ч

5

/

8

" (4

Ч

16 mm)

8

2

AAA alkaline
battery

2

10

Tapping screw

Truss-head
Phillips

5

/

32

Ч

13

/

32

" (4

Ч

10 mm)

2

Parts

Figure

Q’ty

Remote
control unit

Remote control
unit holder

Air clean filter

1

1

Flare insulation

Drain hose

adapter

CAUTION

Check local electrical codes

and regulations before

obtaining wire. Also, check

any specified instructions or

limitations.

Model

Narrow Tube

Wide Tube

Outer Dia.

Thickness

Outer Dia.

Thickness

KS3082

3/8" (9.52 mm)

0.0314" (0.8 mm)

5/8" (15.88 mm)

0.0393" (1.0 mm)

KS3682

3/8" (9.52 mm)

0.0314" (0.8 mm)

5/8" (15.88 mm)

0.0393" (1.0 mm)

10-018 C3082-3682 2/15/10 11:50 AM Page 3