Sony STORSTATION LIB-D81 User Manual
Page 48

48
Appendix
22
Detected SCSI parity error.
Command phase retried but
gave up.
—
Yes
23
Detected SCSI parity error.
Data Out phase retried but
gave up.
—
Yes
24
Detected a parity error
message. Message In phase
retried but gave up.
—
Yes
25
Received Initiator detected
error message. Message
phase retried but gave up.
—
Yes
26
Received Initiator detected
error message. Command
phase retried but gave up.
—
Yes
27
Received Initiator detected
error message. Status phase
retried but gave up.
—
Yes
28
Received Initiator detected
error message. Data In phase
retried but gave up.
—
Yes
29
Received Initiator detected
error message. Data Out
phase retried but gave up.
—
Yes
2A
Received an illegal message
from the SCSI interface.
—
Yes
2B
Received an illegal Identify
message at the SCSI interface
—
Yes
2C
Failed reselection. Reselection
retried but gave up.
—
Yes
2F
REQ/ACK handshake timeout
or controller chip interruption
timeout at the SCSI interface.
—
Yes
30
Reports a unit attention event.
—
Yes
31
An as yet unsupported LUN
specified at the SCSI
interface.
—
Yes
32
Loader not yet ready.
—
Yes
33
Loader front door open.
—
Yes
34
Currently in reprogramming
mode.
—
Yes
35
Currently in menu mode.
—
Yes
36
Reported an information
exception condition.
—
Yes
41
Reception of drive data
timeout at the drive interface.
[L ] and [4 1] appear
alternately on the message
display.
Yes
42
Received data of abnormal
length from drive at the drive
interface.
[L ] and [4 2] appear
alternately on the message
display.
Yes
43
Drive detected as offline at the
drive interface.
[L ] and [4 3] appear
alternately on the message
display.
Yes
70
Detected calibration error
(lower sensor readings
abnormal).
[L ] and [7 0] appear
alternately on the message
display.
Yes
Error code Description
Display
Logged