beautypg.com

Superior SLBV-40PM User Manual

Page 26

background image

Electronic Appliances

Step 8. dexen Electronic Valves: Refer to

Figure 34 and the instructions pro-

vided with the kit.
a. Remove and discard the two pres-

sure regulator mounting screws.

b. Remove the pressure regulator and

diaphragm.

c. discard all removed components.
d. Make sure the provided diaphragm

is installed properly onto the re-

placement pressure regulator.

e. Install the new pressure regulator

using the new screws supplied with

the kit; tighten the screws.

Step 6. (Millivolt systems only): Attach ma-

nometer to the manifold side pressure

test fitting and verify manifold pressure

reads 3.5 inches water column (0.87

kPa) for natural gas, and 10.0 inches

water column (2.49 kPa) for propane

gas.

Step 7. (Millivolt systems only): Refer to Figure

33. Remove the pilot hood assembly to

access the hexed pilot orifice. Remove

and replace the orifice with the one

provided in the kit.

Skip to Step 10.

Figure 32: SIT Millivolt System

Pressure

Regulator

Remove

These

Components

Figure 33: SIT Millivolt System

Pilot
Orifice

Figure 34: Dexen Electronic Gas Valve

Supply Gas

Inlet

Pressure-Tap

(Manifold)

Regulator

Mounting

Screw

Burner Stage

Terminal

Gas

Outlet

To Burner

Ground (TP)

Pilot Stage

Terminal

Pilot Gas Outlet

Pressure-Tap

(Inlet)

PILOT

OUT

VENT

LO

TH TP

TH

TP

HI

IN

IN

Figure 31: SIT Millivolt System

Burner Assembly

Gas Valve

Assembly

Orifice

Step 11. Reassemble the remaining compo-

nents by reversing the procedures

outlined in the preceding steps.

Step 12. Attach the conversion label (provided

in the conversion kit) next to the rat-

ing plate on the appliance.

Step 13. Turn on gas supply and test for gas

leaks (refer to Page 16).

ALWAYS TEST PRESSURES WITH THE VALVE

REGULATOR CONTROL AT THE HIGHEST

SETTING.

All Models

Note the following:
Use pipe joint compound or Teflon tape on

all pipe fittings before installing.
Ensure propane-resistant compounds are

used in propane applications.
Do NOT use pipe joint compounds on flare

fittings.

Step 10. Refer to Figure 31.

a. VERIfY PROPER ORIfICE SIzE

BEfORE INSTALLING IT.

b. Remove the orifice from the mani-

fold and replace it with the one

provided in the kit. See Table 7 for

orifice sizes for natural and propane

models. Figure 36 illustrates the

orifice. Always check and verify

orifice size.

c. Retrieve the burner. Slide the venturi

tube over the orifice.

d. Adjust the burner air shutter as

shown in Figure 26 on Page 21.

Figure 36

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Series

Nat.Gas

drill size (inches)

Propane

drill size (inches)

SLBV-35

#48 (0.076")*

H1236•

#56 (0.046")*

62L37•

SLBV-40

#43 (0.089")*

99K75•

#55 (0.052")*

19L52•

Table 7

*

Standard size installed at factory.

Part /Cat. Number.

Step 9. Refer to Figure 35. Follow these steps

to replace the pilot orifice:
a. Remove pilot hood assembly to

access the phillipped pilot orifice.

b. Remove and replace the orifice

with the one provided with the kit.

Exercise extreme care to prevent

damage to or breakage of the

igniter assembly.

SUPERIOR

®

B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS

26

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 35: Dexen Electronic System

ELECTRONIC

Pilot

Hood

Sensor

Igniter

This manual is related to the following products: