Millivolt wiring diagram, Electronic ignition wiring diagram, J-box/receptacle wiring – Superior SLBV-40PM User Manual

Page 13: Figure 12, Figure 13 figure 14

background image

SUPERIOR

®

B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS

13

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 12

MILLIVOLT WIRING dIAGRAM

CAUTION: WHEN SERVICING CONTROLS, LABEL ALL WIRES PRIOR TO dISCONNECTION.

WIRING ERRORS CAN CAUSE IMPROPER ANd dANGEROUS OPERATION.

VERIfY PROPER OPERATION AfTER SERVICING.

If any of the original wire must be replaced,

use Type AWM 105º C - 18 gage wire ONLY.

High Limit Switch

Control Switch*

Gas Control

Valve Terminals

Thermopile

HI

L O W

PILO

T

PIL

OT

ON

ti

OFF

IN

OUT

TH

TP

HT

PT

B-VENT APPLIANCES ONLY: The High Limit

Switch must be factory installed in series,

as shown. If wires to this switch must be

replaced, use Type AWM 200°C - 18 gage

wire ONLY.

_________
*Control switch options: ON/OFF wall switch, unit-mountable

ON/OFF switch, or ON/OFF remote control system (see "Accessory

Components" in the Care and Operation Instructions).

ELECTRONIC IGNITION WIRING dIAGRAM

_________
*Control switch options: ON/OFF wall switch, unit-mountable

ON/OFF switch, or ON/OFF remote control system (see "Accessory

Components" in the Care and Operation Instructions).

TRANSFORMER 3V

BROWN

BROWN

BLACK

BATTERY BACK-UP

BLACK (SENSOR)

BLACK (IGNITER)

IGNITER MODULE

3V

RED

PILO

T

IN

OUT

VENT

LO

HI

TH

TP

TH

TP

IN

ORANGE (THTP)

BLACK (TP)

GREEN (TH)

HIGH LIMIT SWITCH

Pilot Burner

Pilot Tube

Assembly

Schematic Representation Only

Electronic Gas Control Valve - DEXEN

B-Vent appliances only - High limit

switch must be factory installed as

shown. If wires to this switch are

replaced, wires must be Type AWM

200°C - 18 gage wire ONLY.

CONTROL

SWITCH *

UNIT MOUNTED

ON/OFF SWITCH,

IF SUPPLIED

Junction Box

J-Box Wiring

BK

W

G

CA

V 0

21

* Control Switches: Wall On/Off

Switch, Unit Mounted On/Off Switch

or Remote Control Switch.

NOTES:

1. If any of the original wire as supplied

must be replaced, use Type AWM

105°C - 18 gage wire ONLY.

2. 120 VAC, 60 Hz - Less than 3 Amps.

CAUTION: label all wires prior to

disconnection when servicing controls.

Wiring errors can cause improper and

dangerous operation. Verify proper

operation after servicing.

See Figure 14 for detailed drawing of junction box / receptacle wiring.

Figure 13

Figure 14

J-BOX / RECEPTACLE WIRING

120V, 60HZ, 1PH

Green Ground

Screw

Tab Intact

Green

Neutral Side

of Receptacle

120 V

AC - Black

Neutral - White

Ground - Green

Junction Box

Field Wired
Factory Wired

Hot Side of

Receptacle

Black

Tab Intact

White

J-BOX/RECEPTACLE WIRING