beautypg.com

Caution, Warning, Installation accessories – Superior SLBV-40PM User Manual

Page 14

background image

SUPERIOR

®

B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS

Step 5.

[OPTIONAL]

Install Outside

Combustion Air Kit

An optional outside combustion air kit (model

FOAK-4, FOAK-4LD, or DK-4) may be used

with these appliances (see "Installation Acces-

sories," at right).

Refer to the instructions included with the

air kits for specific installation information.

If used, the outside air kit must be installed

before the fireplace is framed and enclosed in

the finished wall.

Outside air drawn into the fireplace supplies

supplemental combustion air to the fire. Only

one outside air duct is necessary, if installed.

If additional length of duct is necessary, pur-

chase locally available U.L. Class 0 or Class 1

metallic ducting. The duct may extend up to 50'

(15.24 m) in one continuous piece.

Note: When installing the air duct vertically, do

NOT terminate the duct closer than 3' below

the chimney top.

Outside supplemental combustion air ducting

may be run upward or vertically through fram-

ing and ceiling joists, with the hood installed

through an outside wall and 3' (1 m) below the

termination. Ducting may also be run down-

ward through floor joists and under the home

to a ventilated crawlspace not considered part

of the living area of the home.

Note: NEVER terminate an outside supple-

mental combustion air kit in attic space

under any circumstances.

After completing installation of the optional

outside air vent system the outside air control

lever must be put in service and tested to en-

sure proper operation before completing any

enclosure around the firebox.

Failure to do so may result in extensive and

costly rework. Before the operation of the vent

system can be tested, the lever securing screw

must be removed. See Figure 15.

The hand-operated outside air control lever

is located on the left side of the lower control

compartment opening. See Figure 15.

To open the outside air shutter, open the bottom

control access panel, reach into the control com-

partment, and pull the outside air control lever

all the way out. The outside air shutter should

be fully open when the fireplace is in use and

completely closed when the fireplace is not being

used. Closing it when not in use will help limit the

amount of outside cold air entering the dwelling.

Operate the actuator through several cycles

including the closed position. Ensuring proper

operation and freedom of movement. Return

the actuator arm to the closed position.

CAUTION

Never locate inlet where it can be

blocked by shrubs, snow drifts,

etc. Never locate inlet in garage

or any area where there is another

fuel burning appliance or products

emitting combustible gases such

as paint, gasoline, etc. In cold

climates, it is recommended the

outside air duct be insulated.

INSTALLATION ACCESSORIES

The following accessory items are available for

use in the installation of this appliance.

Outside Combustion Air Kits

Cat. No.

Model No.

description

81L87

fOAK-4

Combustion Air Kit (w/duct)

81L88

fOAK-4Ld

Combustion Air Kit (w/o duct)

H5377

dK-4

Single 4" duct Kit

Outside Combustion Air Kits

Models fOAK-4 and fOAK-4Ld

Outside combustion air kits are available with

duct (FOAK-4) and without duct (FOAK-4LD)

for use if supplemental outside combustion

air is required or desired. If model FOAK-4LD

is used, it must be used in conjunction with

locally purchased, non-combustible Class 1 or

Class 0 flexible duct.

14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

WARNING

do not operate the shutoff lever

unless a complete outside com-

bustion air system has been

installed with your appliance.

Left Side of

Lower Control Compartment

Figure 15

Securing

Screw

Removed

Outside Air Control

Lever pulled DOWN

(Air Shutter OPEN)

Outside Air Control

Lever pushed UP

(Air Shutter CLOSED)

Securing

Screw

Installed

IMPORTANT: Do NOT move Air Control

Lever if securing screw is installed

(or if not sure it was removed).

This manual is related to the following products: