beautypg.com

Schumacher Automatic SP2 User Manual

Page 11

background image

• 10 •

USiNG THE QUiCK-CONNECT CABLE CONNECTORS

There is a 2 amp, inline fuse in the cable assemblies to prevent

damage to the charger, if it is connected to a battery incorrectly. If the

charger does not charge the battery, check the fuse. If the fuse needs

replacing, only replace it with a fuse of the same size and rating.

NOTE: Never connect the clamp and ring terminal connectors

together for use in other applications, such as external battery or

other power source charging, or to extend the output cable length, as

reverse polarity and/or overcharge conditions will occur.

50 Amp Battery Clips

Connect the end of the charger output cable to the end of the

1.

50-amp battery clips cable.

Follow the steps in sections 6 and 7 to connect the output clips

2.

to the battery.

After a good electrical connection is made to the battery, plug

3.

the power cord into a grounded 120V AC electrical wall outlet.

Make sure to place the charger on a dry, non-flammable

surface, such as metal or concrete.

Permanent Ring Connectors

To permanently attach to a battery, loosen and remove each nut

1.

from the bolt at the battery terminals.

Connect the red POSITIVE connector ring to the POSITIVE

2.

(POS, P, +) battery terminal.

Connect the black NEGATIVE connector ring to the NEGATIVE

3.

(NEG, N, -) battery terminal.

Replace and tighten the nuts to secure.

4.

Connect the ring connector cable assembly to the charger.

5.

Take care to keep both wires and plug away from hot and

moving parts.

Plug the charger power cord into a grounded 120V AC

6.

electrical wall outlet. Make sure to place the charger on a dry,

non-flammable surface, such as metal or concrete.

Automatic Charging Mode

When an Automatic Charge is performed, the charger switches to the

Maintain Mode (see below) automatically after the battery is charged.