This is not intended to be and all-inclusive list of the problem that the Service Agent may encounter. Any item checked “no” on
this list should be thoroughly investigated and corrective action taken, if required.
SERVICE AGENT:
INSTALLATION DATE:
MODEL NUMBER:
SERVICE DATE:
SERIAL NUMBER:
LOCATION ADDRESS:
PHONE
( )
-
GAS
TYPE — CHECK ONE
NATURAL
PROPANE
PROPER GAS VALUE VERIFIED
YES
NO
I.
CHECK CLEARANCE (CIRCLE ANSWER)
A.
Are exterior clearances adequate?
yes
no
B.
Are interior clearances adequate?
yes
no
Comments:
II.
CHECK MAKEUP AIR REQUIREMENTS
A.
Is the quality of make-up air adequate?
yes no
Comments:
B.
Is the quantity of make-up air adequate?
yes
no
Comments:
III. GAS PRESSURE (FILL IN BLANK) — ALL UNITS ON.
A.
Supply gas pressure __ inches of W.C. (flowing)
B.
Manifold gas pressure (main burner) __ inches of W.C. (flowing)
Comments:
IV. VENTING (CHECK)
A.
Acceptable equivalent footage
yes
no
B.
Proper material
yes
no
C.
Proper exterior installation
yes
no
D.
Condensate will drain
yes
no
Comments:
V.
WATER PIPING
Is the system properly sized?
yes
no
Is the system properly installed?
yes
no
Are there any water leaks?
yes
no
Does the installation have a recirculating system?
yes
no
If so, is it operational?
yes
no
VI. SAFETY
A.
Air
If exhaust is blocked will unit lockout?
If air intake is blocked will unit lockout?
yes
no
yes
no
B.
Water Temperature
- Is the thermostat adjusted to the lowest acceptable temperature?
yes
no
- Does the installation have a mixing valve?
yes
no
- If so, is it operational?
yes
no
- What is the outlet temperature of the mixing valve?
yes
no
NOTE: To minimize the risk of scalding, the manufacturer recommends storing water at 120° F.
Is a properly rated temperature and pressure relief valve installed?
yes
no
Is there a properly installed expansion tank?
yes
no
Should there be?
yes
no
C.
Electrical
Is the 120 VAC electrical powers supply properly wired? (including polarity)
yes
no
Are all the SUF control covers in place?
yes
no
Is the 120 VAC electrical power supply properly fused?
yes
no
D.
Flammables
Are flammable materials located in the area of the water heater? or air intake?
yes
no
Are flammable vapors located in the area of the water heater? or air intake?
yes
no
E.
Gas
If the gas supply is reduced or turned off will the unit turn off?
yes
no
Comments: