Pressure switches (continued) – State Industries Utra-Force STC-077 User Manual
Page 35
![background image](/manuals/144368/35/background.png)
S U F S E R V I C E H A N D B O O K
C O M P O N E N T I N F O R M A T I O N
Technical Training Department
State Water Heaters
STC-077
34
Ashland City, Tennessee © 2004
PRESSURE SWITCHES (CONTINUED)
PRESSURE SWITCHES
PART NUMBER / ACTIVATION PRESSURE
†
†. Pressure values are given in inches of water column pressure (“W.C.).
Negative pressure values in this table are preceded by a “-” minus sign and indicate pressure below
atmospheric; in a vacuum. Positive pressures are preceded by a “+” plus sign and indicate pressure above
atmospheric.
Model
Blocked Inlet
Normally Closed
Opens on a fall
Blower Prover
Normally Open
Closes on a rise
Low Gas Pressure
Normally Open
Closes on a rise
Blocked Outlet
Normally Closed
Opens on a rise
SUF 150
193363-000 / -0.76”
194706-000 / +1.00”
N/A
193362-000 / +2.60”
193355-000 / -1.80”
194706-000 / +1.00”
N/A
193357-000 / +4.00”
193355-000 / -1.80”
194706-000 / +1.00”
N/A
193357-000 / +4.00”
SUF 199
193363-000 / -0.76”
194706-000 / +1.00”
N/A
193364-000 / +2.87”
193356-000 / -2.00”
194706-000 / +1.00”
N/A
193357-000 / +4.00”
193356-000 / -2.00”
194706-000 / +1.00”
N/A
193357-000 / +4.00”
SUF 240
193361-000 / -0.77”
194706-000 / +1.00”
191149-005 / +5.20”
193357-000 / +4.00”