S U F S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

Technical Training Department

State Water Heaters

STC-077

24

Ashland City, Tennessee © 2004

PRESSURE SWITCH CONTINUITY

STEP 7: CHECK FOR CONTINUITY BETWEEN PRESSURE SWITCH TERMINALS WITH
WIRES REMOVED.
Condition:

• On/Off switch is off.
• All wires are disconnected from all pressure switches.
• Multimeter is set to lowest ohms scale.

STEP 7

PRESSURE SWITCH CONTINUITY TEST

IF…

THEN

blocked inlet switch does not show continuity

replace switch.

blocked inlet switch does show continuity

continue.

blower proving switch does show continuity

replace switch.

blower proving switch does not show continuity

continue.

low gas pressure switch does not show continuity

check for minimum supply gas
pressure of
5.0” W.C. natural gas
9.0” W.C. LP gas
replace switch if gas pressures
are above these minimums.

low gas pressure switch does show continuity

continue.

blocked outlet pressure switch does not show continuity

replace switch.

blocked outlet pressure switch does show continuity

reconnect all wires to pressure
switches; continue to Step 8.