Sharp DX-B450P User Manual
Page 35

User’s Guide
3-9
Operator Panel Menus
Operator Panel
Delay Out Close
On/Off
Off
When ON, the printer will wait until the job
is completely printed and delivered to the
output tray before terminating the
connection, allowing all reverse-channel
data to be sent back to the host. This will
cause a reduction in printer throughput.
When OFF, reverse-channel data generated
after the job interpretation is discarded. No
reduction in printer throughput occurs.
Binary PS
On/Off
On
When On, the feature allows all binary codes
to be processed by the PostScript interpreter.
When Off, special binary control codes may
be intercepted per the Format item setting.
Serial Setup
Submenu
Interpreter
Auto Switch
PCL
PostScript 3
Auto Switch
Format
Raw
Normal
Binary
Raw
Configures how incoming print jobs are
scanned for special binary control codes.
RAW=no processing
Normal = “Adobe Standard Protocol” (ASP)
Binary = “Binary Control Protocol” (BCP)
When Interpreter setting is Auto Switch and
this setting is Raw, the printer will
automatically determine the control code
method, defaulting to Normal if no codes are
found.
Serial Mode
RS232
RS422
RS232
Serial mode
Baud Rate
1200, 2400,
4800, 9600,
19200, 38400,
57600, 115200
9600
Serial baud rate
Data Bits
8, 7
8
Serial data bits
Stop Bits
1, 2
1
Serial stop bits
Parity
None
Even
Odd
None
Serial parity
DTR Ready/Busy
On/Off
Off
If On, the DTR signal will reflect the Ready/
Busy status.
DTR On1/Off1
On/Off
Off
If On, the DTR signal will reflect the Online/
Offline status.
DTR Error
On/Off
Off
If On, the DTR signal will reflect the Error
status.
RTS Ready/Busy
On/Off
Off
If On, the RTS signal will reflect the Ready/
Busy status.
Menu Item
Value
Default
Description