beautypg.com

Service call check, Troubleshooting chart – Sharp AX-700 User Manual

Page 36

background image

A42378,SEC AX700S O/M

34

S E R V I C E C A L L C H E C K / T R O U B L E S H O O T I N G C H A R T

Press STOP/CLEAR and check that installation is correct.
Check page 3. Be sure there is sufficient space surround-
ing the oven for proper performance. If there is sufficient
space, descale by following the instructions on page 31.

Press STOP/CLEAR and drain the water using DRAIN
WATER instructions on page 13.

Press STOP/CLEAR and descale using DESCALE in-
structions on page 31. Should these steps not restore
the oven performance or should there be other error num-
bers in the display, disconnect the oven from the wall
outlet, call or carry-in the oven to a Sharp Authorized
Servicer.

* There is not enough water in the reservoir for the

chosen cooking operation. Remove reservoir and fill
with water to the MAX mark. Place in the reservoir
cavity correctly and push firmly into place. Press
START.

* If START pad is pressed while the oven is checking

the water amount, this message may be displayed.
Press START pad again.

Remove the reservoir. Place in the reservoir cavity cor-
rectly and push firmly into place. Press START again.

The oven is too hot to use either DEFROST or PROOF.
Remove the food from the oven and allow oven to cool
until display clears.

Follow step-by-step instructions for descaling on page 31. When
the drained water in the base tray has white or gray grains in it,
the oven needs descaling. The frequency of descaling will de-
pend on the hardness of your water; the harder the water the
more often descaling will be needed. If "Descaling necessary"
appears frequently, you may use distilled water instead of tap
water. This will reduce, but not eliminate, the need to descale.

* Remove the reservoir and check that it is filled, the air holes

are not clogged, the reservoir filter is not clogged and that
there is no damage to the reservoir. When filled to the MAX
mark, position the reservoir correctly and push firmly into
place. Reprogram and touch START.

* If message is still in the display, follow step-by-step instruc-

tions for descaling on page 31.

* If message is still in the display, call or carry-in the oven to

a Sharp Authorized Servicer.

SERVICE CALL CHECK

If EE is displayed or you think the oven is not working properly, check the chart below before consulting
a Sharp Authorized Servicer. This will help to prevent unnecessary service calls.

TROUBLESHOOTING CHART

ERROR MESSAGE / INFORMATION MESSAGE

ERROR
MESSAGE

INFORMATION
MESSAGE

EE05

EE12

EE15

Fill reservoir.

Check reservoir position.

Wait until oven is cool.

Descaling necessary

Water cannot be pumped.

MESSAGE ON DISPLAY

ACTION

SEC AX700S O/M,P30-

05.4.8, 1:44 PM

34