Camera Initial Settings
Setting Baud Rate Based on DVR Model
If the speed dome camera is controlled not by the camera controller but by a
DVR, set the communication speed based on the DVR model as follows.
Part Names and Functions
• Default Setting : Samsung 9,600 bps
• AD, Bosch is now preparing.
Notes
Setting Communications Protocol
Use the SW2 #1~#5 of installation bracket to set the communications protocol.
NO.
Protocol
Baud Rate(BPS)
SW2-#1
SW2-#2
SW2-#3
SW2-#4
SW2-#5
1
Samsung
9,600
OFF
OFF
OFF
OFF
OFF
2
Samsung
19,200
OFF
OFF
OFF
OFF
ON
3
Pelco-D
2,400
OFF
OFF
OFF
ON
OFF
4
Pelco-D
4,800
OFF
OFF
OFF
ON
ON
5
Samsung Elec.
9,600
OFF
OFF
ON
OFF
OFF
6
Samsung Elec.
19,200
OFF
OFF
ON
OFF
ON
7
Panasonic
9,600
OFF
OFF
ON
ON
OFF
8
Panasonic
19,200
OFF
OFF
ON
ON
ON
9
Vicon
4,800
OFF
ON
OFF
OFF
OFF
10
Vicon
9,600
OFF
ON
OFF
OFF
ON
11
AD
4,800
OFF
ON
OFF
ON
OFF
12
Bosch
9,600
OFF
ON
OFF
ON
ON
13
Bosch
19,200
OFF
ON
ON
OFF
OFF
14
Honeywell
9,600
OFF
ON
ON
OFF
ON
15
Honeywell
19,200
OFF
ON
ON
ON
OFF
16
Sungjin
4,800
OFF
ON
ON
ON
ON
17 32
Reserve
Setting Transmission Mode
Set the transmission mode using the ON/OFF of the Dip Switch 2.
Samsung
Pelco
Samsung Elec.
SVR-950
9600,19200
2400,4800
19,200
SVR-1640
9600,19200
2400,4800
19,200
SVR-1650
9600,19200
2400,4800
19,200
Protocol
DVR Model
Function
ON
OFF
SW2- #6
Transmission Mode
Full
Half
Selection
(DVR)
(SCC-3100A)
• Factory Setting: OFF
Notes