11: Regulatory Information
Canada
Note:
Unauthorized modifica-
tions or changes not expressly
approved by Sierra Wireless,
Inc. could void compliance with
regulatory rules, and thereby
your authority to use this
equipment.
To ensure that the MP modem meets Health Canada’s Safety
Code 6 requirements, a separation distance of at least 20 cm
(8 inches) must be maintained between the modem’sMain RF
antenna and the body of the user and any nearby persons at all
times and in all applications and uses.
Additionally, the maximum antenna gain in the PCS band,
including cable loss, must not exceed 4.15 dBi, and in the
Cellular band, must not exceed 5.1 dBi, to comply with
Industry Canada and Health Canada regulations limiting both
maximum RF output power and human exposure to RF
radiation.
For the MP 595W modem, the maximum gain for the AP
antenna must not exceed 3 dBi, and the AP antenna must be at
least 20 cm away from the Main RF antenna.
U.S.A.
To comply with FCC regulations limiting both maximum RF
output power and human exposure to RF radiation, the
maximum antenna gain, including cable loss, in the PCS band,
must not exceed 4.15 dBi, and in the Cellular band, must not
exceed 5.1 dBi.
The Main RF Main RF antenna must be mounted such that
there is a separation distance of at least 20 cm (8 inches)
between the Main RF antenna and the body of the user or any
nearby persons.
For the MP 595W modem, the maximum gain for the AP
antenna must not exceed 3 dBi, and the AP antenna must be
professionally installed with a separation distance of at least 20
cm away from the Main RF antenna, per FCC Part 15 require‐
ments.