The fast rate timer only becomes active when an alarm 
condition is triggered by a rise or drop in the level of one of the 
digital I/O channels. The default for the fast rate timer is three 
seconds. 

Note: When the fast rate timer is set to 0, a single report is sent when
an I/O alarm is triggered.

If the GPS timer is set to a value other than 0, it controls the 
frequency of reports in the absence of any alarm or event 
triggers. (However, if the GPS timer is set to a longer interval 
than the low rate timer, the value for the low rate timer will 
determine report frequency.)

MP modem

Host

Fast rate timer = 3 seconds
Low rate timer = 5 minutes
GPS timer = 10 seconds

10 seconds

10 seconds

3 seconds

3 seconds

Digital I/O alarm

TM_SUM_REG_IND

TM_SUM_REG_IND

TM_SUM_REG_IND

TM_SUM_REG_IND

TM_SUM_REG_IND

TM_SUM_REG_IND