3-2. Address setting
Before setting of address by DIP switch, turn power supply for communication cable in SI
unit “OFF”.
Setting (binary) of following items is available by DIP switch installed to cover.

1) Node address (00 to 63)
2) Communication speed (125kbps, 250kbps, 500kbps)

- 8 -

SMC CORPORATION

Doc.No.EX

##

-OME0015

SW1

SW2

SW3

SW4

SW5

SW6

Node

address

1

2

4

8

16

32

#0

0

0

0

0

0

0

#1

1

0

0

0

0

0

#2

0

1

0

0

0

0

:
:
:

#62

0

1

1

1

1

1

#63

1

1

1

1

1

1

Setting

Max. transmission distance (m)

Length of trunk

SW7 SW8

Communication

speed (kbps)

Thick
cable

Think

cable

Length

of

branch

line

Total length

of

branch line

0

0

125

500

156

1

0

250

250

78

0

1

500

125

100

6

39

1

1

Not used

Not used

CAUTION

• When shipped, node address of 63 and communication speed of 125kbps are set in
advance.
• When communication error occurs, output condition is cleared.