Star Micronics SLIP SP298 User Manual
Page 59

56
3)
N=2
n1 :Always “0”
n2 :Always “0”
n3 :Always “0”
n4 :Always “0”
4)
N=3 (Star mode only)
n1 :Always “0”
n3 :Always “0”
(Default)
5)
N=4 (Star mode)
n3 :Always “0”
n4 :Always “0”
(Default)
N=4 (ESC/POS mode)
n1 :Always “0”
(Default)
Parameter
Setting
“
0
”
“
1
”
“
2
”
“
3
”
n2
Character table
See below
n4
CR code
Invalid
Invalid
Valid
Valid
n2 Character table
n2 Character table
n2 Character table
“0” Normal
“4” Code page 858
“8” Code page 863
“1” Katakana
“5” Code page 852
“9” Code page 865
“2” IBM (Code page 437)
“6” Code page 860
“A” Code page 866
“3” IBM (Code page 437)
“7” Code page 861
Parameter
Setting
“
0
”
“
1
”
“
2
”
“
3
”
n1
X on/X off Timing
When
Toggled
every 3
sec
When
Toggled
every 3
sec
RTS Signal Condition
Save as
DTR
Save as
DTR
always
SPACE
always
SPACE
n2
Receive buffer size
2k bytes
2k bytes
35 bytes
35 bytes
Parameter
Setting
“
0
”
“
1
”
“
2
”
“
3
”
n2
Receive buffer size
512 bytes
(TM-295)
2k bytes
(TM-290)
512 bytes
(TM-295)
2k bytes
(TM-290)
35 bytes
35 bytes
n3
DSR signal check
during setting status
transmission
Checked Checked
Not
checked
Not
checked
n4
Data receipt error
"?"
printed
Ignored
"?"
printed
Ignored