beautypg.com

Communications protocol – Sanyo VCC-MD500 User Manual

Page 20

background image

− 19 −

Communications Protocol

Model: VCC-MD400/300

Message

Query Command

Response Command

Zoom

Tele/Wide Speed

80

02

08

CS

FF

C0

02

08

0p

CS

FF

Configured Tele/Wide Speed

1: speed1, 2: speed2, 3: speed3, 4: speed4

Direct

80

02

09

CS

FF

C0

02

09

0p

0q

0r

CS

FF

Current Zoom Lens Position

Direct Position D/N Model 0:Wide 2069:Tele

Color Model 0:Wide 2488:Tele

Focus

Far/Near Speed

80

03

08

CS

FF

C0

03

08

0p

CS

FF

Configured Far/Near Speed

1: speed1, 2: speed2, 3: speed3, 4: speed4

Direct

80

03

09

CS

FF

C0

03

09

0p

0q

0r

CS

FF

Current Focus Lens Position

Direct Position D/N Model 0:Far 3524:Near

Color Model 0:Far 4008:Near

White Balance

MWB Red Direct

80

04

13

CS

FF

C0

04

13

0p

0q

CS

FF

MWB R Component Set Value

Direct 0-255

MWB Blue Direct

80

04

1D

CS

FF

C0

04

1D

0p

0q

CS

FF

MWB B Component Set Value

Direct 0-255

Iris

Iris Level Direct

80

05

13

CS

FF

C0

05

13

0p

0q

CS

FF

Iris Level Set Value

Direct 0-100

Iris Stop Direct

80

05

1D

CS

FF

C0

05

1D

0p

CS

FF

Iris Aperture Set Value

1-17

Sync

L-L Phase Direct

80

09

13

CS

FF

C0

09

13

0p

0q

0r

CS

FF

Power Source Synchronous Set Value

Direct 0-524(NTSC) / 0-624(PAL)

AGC

Max Gain at AGC (

COLOR

80

0A

09

CS

FF

C0

0A

09

0p

CS

FF

AGC MAX Gain Set Value (D/N camera set value when in COLOR)

0: OFF, 1: -6dB, 2: 0dB, 3: 6dB, 4: 9dB

Max Gain at AGC

BW)

80

0A

0A

CS

FF

C0

0A

0A

0p

CS

FF

AGC MAX Gain Set Value during B/W

0: OFF, 1: -6dB, 2: 0dB, 3: 6dB, 4: 9dB,

5: 12dB, 6: 15dB

Max Gain at AGC (

AUTO)

80

0A

0B

CS

FF

C0

0A

0B

0p

CS

FF

AGC MAX Gain Set Value during AUTO

4: 9dB, 5: 12dB, 6: 15dB

Gain Direct

COLOR

80

0A

13

CS

FF

C0

0A

13

0p

CS

FF

Gain Settings when COLOR and AGC are OFF

0: 0dB, 1: 3dB, 2: 6dB, 3: 9dB, 4: 12dB,

5: 15dB, 6: 18dB, 7: 21dB, 8: 24dB,

9: 27dB, 10: 30dB

Gain Direct

BW

80

0A

14

CS

FF

C0

0A

14

0p

CS

FF

Gain Settings when B/W and AGC are OFF

0: 0dB, 1: 3dB, 2: 6dB, 3: 9dB, 4: 12dB,

5: 15dB, 6: 18dB, 7: 21dB, 8: 24dB,

9: 27dB, 10: 30dB

Aperture

Aperture V Direct

80

0B

13

CS

FF

C0

0B

13

00

0p

CS

FF

Vertical Contour Compensation Set Value

1-15

Aperture H Direct

80

0B

1D

CS

FF

C0

0B

1D

00

0p

CS

FF

Horizontal Contour Compensation Set Value

1-15

Privacy Masking

Mask Position

80

10

09

0p

CS

FF

C0

10

09

0p

0q

0r

0s

0t

0u

CS

FF

Privacy Mask Position

Refer to "Function Descriptions [1

1]Privacy

Mask Setting"

OSD MENU

Menu No

80

16

01

CS

FF

C0

16

01

0p

CS

FF

Current Display MENU No.

View Setting

View Setting No

80

18

01

CS

FF

C0

18

01

0p

CS

FF

Current Display View Angle File No.

EEPROM Access

EEPROM Access

80

19

01

0p

0q

0r

CS

FF

C0

19

01

0p

0q

0r

0s

0t

CS

FF

Value Written to EEPROM

pqr: Address 0-2047 st: Data 0-255

DAY/NIGHT

D/N LEVEL

80

28

05

CS

FF

C0

28

05

0p

CS

FF

Color/Black and White Switch Level Set Value

0: LOW, 1: MID, 2: HIGH, 3: ADJ

D/N ADJ DIRECT (C->B/W)

80

28

06

CS

FF

C0

28

06

0p

CS

FF

Color

Black and White Switch Level

Manual Set Value

0-6

D/N ADJ DIRECT (B/ W->C)

80

28

07

CS

FF

C0

28

07

0p

CS

FF

Black and White

Color Switch Level

Manual Set Value

0-6

D/N FOCUS SET (AUTO)

80

28

08

CS

FF

C0

28

08

0p

CS

FF

Focus Mode Set Value during D/N AUTO Black and White

0: MODE1, 1: MODE2

D/N FOCUS SET (B/W)

80

28

09

CS

FF

C0

28

09

0p

CS

FF

Focus Mode Set Value during Black and White

0: MODE1, 1: MODE2

Status

Status

80

4A

01

CS

FF

C0

46

01

0p

0q

0r

0s

0t

0u

CS

FF

(Note 2)

Status type 2

*1

80

4A

02

CS

FF

C0

46

02

0p

0q

0r

0s

0t

0u

0v

0w

0x

0y

CS

FF

Status type 3

*1

80

4A

03

CS

FF

C0

46

03

0p

0q

0r

0s

0t

0u

CS

FF

Rom Version

80

4A

0A

CS

FF

C0

46

0A

0p

0q

CS

FF

pq: Version

*1: Only MD400

CS: Checksum

*2: Only MD300

FF: Terminator

[6]