Performing auto calibration – Sony R-DG1200 User Manual

Page 108

background image

108

US

D:\NORMAN_PC\JOBS\SONY HA\STR-DG1200\U\3289135111\01US-
STRDG1200CEL\090OTH.fm

masterpage: Left

STR-DG1200

3-289-135-11(1)

For details on the Auto Calibration, see “9:
Calibrating the appropriate speaker settings
automatically (Auto Calibration)” (page 41).
See “Before you perform the Auto
Calibration” (page 41) befo
re performing the
Auto Calibration.

To operate on the receiver

1

Press GUI MODE repeatedly to select
“GUI OFF”.

2

Press AMP.
Receiver operation is enabled.

3

Press MENU.

4

Press

V/v repeatedly to select

“< AUTO CAL >”, then press

.

5

Press

V/v repeatedly to select “A.CAL

START”, then press

to start the

measurement.
Measurement starts in five seconds. A
count down is displayed.

Note

While the time is counting down, stand away
from the measurement area to avoid
measurement error.

6

Measurement starts.
The measurement process will take
approximately 30 seconds. Wait until the
measurement process completes.

To cancel Auto Calibration, change the
volume, activate the muting function, switch
functions, change the setting of SPEAKERS
(OFF/A/B/A+B), press GUI MODE, or
connect headphones.

Tips

• Operations other than turning the receiver on or off

are deactivated during Auto Calibration.

• When connecting special speakers, such as dipole

speakers, the measurements may not be performed
correctly or Auto Calibration cannot be performed.

To confirm/save Auto
Calibration when GUI function
is turned off

1

Confirm the measurement result.
When the measurement ends, a beep
sounds and the measurement result appears
on the display window.

2

Press

V/v repeatedly to select the item,

then press

.

3

Select “SAVE EXIT” in step 2.
The measurement results are saved.

Performing Auto Calibration

Measurement
result

Display
window

Explanation

When the
measurement
process
completes
properly

COMPLETE Proceed to step

2.

When the
measurement
process fails

E-
xxx:xx

See “Message
list after Auto
Calibration
measurement”
(page 46)
.

Item

Explanation

RETRY

Performs the Auto Calibration
again.

SAVE EXIT

Saves the measurement
results and exits the setting
process.

WARN CHECK Displays a warning

concerning the measurement
results. See “Message list
after Auto Calibration
measurement” (page 46).

PHASE INFO.

Displays the phase of each
speaker (in phase/out of
phase). See “When you select
“PHASE INFO.”” (page 109).

DIST. INFO.

Displays the measurement
result for speaker distance.

LEVEL INFO.

Displays the measurement
result for speaker level.

EXIT

Exits the setting process
without saving the
measurement results.