beautypg.com

Material safety data sheet – Sharp AR-151 User Manual

Page 48

background image

Date Issued :Nov. 1, 2000

MATERIAL SAFETY DATA SHEET

MSDS No. F-31001

Section 1.

Product Identification

Product
AR-152ND/DV/SD (Black Developer)

Section 2.

Supplier’s Name and Address

Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.

(Country)

(Name and Telephone Number)

U.S.A.

Sharp Electronics Corporation
Telephone number for information: 1-800-237-4277
Emergency telephone number:

1-800-255-3924

Canada

Sharp Electronics of Canada Ltd.
Telephone number for information: 905-890-2100
Emergency telephone number:

1-800-255-3924

United Kingdom

Sharp Electronics (U.K.) Ltd.
Telephone number for information: 01923-474013

Section 3.

Ingredients

Ingredients

CAS No.

Proportion

OSHA PEL ACGIH TLV Other Limits

Iron powder

7439-89-6

> 92.5%

Not listed

Not listed

None

Styrene-Acrylate copolymer

29497-14-1

< 7.0%

Not listed

Not listed

None

Carbon black

1333-86-4

< 0.5%

3.5m

g

/m

3

3.5m

g

/m

3

None

Section 4.

Hazardous Identification (Emergency Overview)

Developer is a black powder containing small amounts of toner, and possessing no immediate hazard.
There are no anticipated carcinogenic effects from exposure based on animal tests performed using
toner.

Section 5.

Health Hazard Data

Route(s) of Entry:

Inhalation?

Skin?

Ingestion?

No

No

Possible but very unusual.

Health Hazards:

Acute oral toxicity ------------- LDL

0

of this toner which is included in this developer

is over 2,000m

g

/k

g

.

Mutagenicity -------------------- The toner, which is included in this developer, has been

tested on Ames test. The result is negative.

Carcinogenicity: In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible

human carcinogen). This classification is given to chemicals for which there is
inadequate human evidence, but sufficient animal evidence on which to base an
opinion of carcinogenicity. The classification is based upon the development of lung
tumors in rats receiving chronic inhalation exposures to free carbon black at levels
that induce particle overload of the lung. Studies performed in animal models other
than rats did not show any association between carbon black and lung tumors.
While there have been no studies to date using developer, a two-year cancer
bioassay using a typical toner preparation containing carbon black (a small amount
of toner is included in the developer mixture) demonstrated no association between
toner exposure and tumor development in rats.

Signs and Symptoms of Exposure: Minimal irritation to respiratory tract may occur as with exposure

to any non-toxic dust.

Medical Conditions Generally Aggravated by Exposure: None
Emergency and First Aid Procedures:

Inhalation;

Remove to fresh air. If effects occur, consult medical personnel.

Eye;