5

Copier trouble?

Push gently on both sides of the front cover to open the cover.

Rotate the feeding roller in the direction of the arrow and gently remove the misfed
paper from the exit area.

Feeding roller

Raise the fusing unit release lever, close the front cover and then close the side cover
by pressing the round projections near the side cover open button. The misfeed (

)

indicator will go out and the ready (

) indicator will light up.

When closing the covers, be sure to close the front cover securely and then
close the side cover. If the covers are closed in the wrong order, the covers
may be damaged.

DEVELOPER REQUIRED

When the

indicator lights up, the developer should be replaced.DEVELOPER

REPLACEMENT SHOULD ONLY BE DONE BY AN AUTHORIZED SHARP SERVICE
TECHNICIAN. Contact your service center as soon as possible.

MAINTENANCE REQUIRED

When

indicator lights up, service by an authorized SHARP service technician is required.

Contact your service center as soon as possible.