beautypg.com

W1773 electrical specifications phase converter – Woodstock SHOP FOX W1772 User Manual

Page 14

background image

-12-

W1772/W1773 37" Drum Sander

EL

EC

TR

IC

A

L

Attempting to connect this machine to

the power source without a qualified

electrician greatly increases the risk

of electrocution, fire, or machine

damage.

W1773 220V/440V 3-

Phase Operation

The Model W1773 is prewired for 220V 3-phase operation,

but may be rewired for 440V 3-phase operation (see

Page

13).

This machine must be hardwired to a locking shutoff

switch by a qualified electrician. Hardwiring involves a

permanent installation with conduit runs that can only be

accomplished safely by a qualified electrician. As always,

observe all applicable electrical codes when connecting

this machine to power.

This machine must be grounded! Verify the ground before

connecting this machine to the power source.

Figure 3. Locking shutoff switch.

Voltage

Amp Draw

Min. Circuit Size

Connection

Cord

Extension Cord

220V

44.3

60A

Hardwire

Conduit Setup

N/A (Hardwire Only)

440V

22.15

30A

Hardwire

Conduit Setup

N/A (Hardwire Only)

W1773 Electrical

Specifications

Phase Converter

The power from the manufactured power leg (wild wire)

of a phase converter fluctuates, which may damage elec-

trical components if connected to the wrong incoming

power terminal. If you must use a phase converter for

3-phase power, only connect the "wild wire" to the L1

terminal. The wire from the L1 terminal can handle some

fluctuation because it goes directly to the motor. The

power going to the L2 and L3 terminals connects to the

controls and must be consistent to prevent damage.

The machine must be properly set up before it is

safe to operate. DO NOT connect this machine to the

power source until instructed to do so in the "Power

Connection" portion of this manual.