Sanyo PLC-WXL46 User Manual
Page 19

PLC-WXE46/WXL46 Basic Serial Command Specifications
19/24
6.53. Computer 1 SCART Command
Command “C51”[CR]
Detail
Select Scart input in Computer1.
Although Input search is set to On1/On2, search is not executed with this
command
Response
Acceptable
[ACK] [CR]
Unacceptable “
”[CR]
6.54. Computer 1 Component Command
Command “C54”[CR]
Detail
Select Componentt input in Computer1.
Although Input search is set to On1/On2, search is not executed with this
command
Response
Acceptable
[ACK] [CR]
Unacceptable “
”[CR]
6.55. AUTO PC ADJ. Command
Command “C89” [CR]
Detail
Execute Auto PC Adj. function.
This command works the same way as “AUTO PC ADJ.” button of the remote
control.
Sending the command during Auto PC Adj. operation stops the operation. This is
the same operation as “AUTO PC” button of the remote control.
Response
Acceptable
[ACK] [CR]
Unacceptable “
”[CR]
6.56. PRESENTATION TIMER Command
Command “C8A” [CR]
Detail
Execute Presentation Timer.
This command works the same way as “P-TIMER” button of the remote control.
Response
Acceptable
[ACK] [CR]
Unacceptable “
”[CR]
6.57. KEYSTONE
↑Command
Command “C8E” [CR]
Detail
Correct keystone distortion by reducing upper part of image.
Response
Acceptable
[ACK] [CR]
Unacceptable “
”[CR]
6.58. KEYSTONE
↓Command
Command “C8F” [CR]
Detail
Correct keystone distortion by reducing down part of image.
Response
Acceptable
[ACK] [CR]
Unacceptable “
”[CR]