Connection, A] [b] [c, B] using the push-lock terminals – Sanyo MPX-MD162 User Manual
Page 7: C] sensor alarm out terminals
CONNECTION
CONNECTIONS TO THE ALARM IN AND RS232C/RS485 TERMINALS
[A] RS485 (RJ-11) terminal connection
Make the connection to the RS485 control terminal using a
modular cable (sold separately).
•
If using a straight type cable, connect it between the A
terminals, or between the B terminals (see illustration below).
•
If using a crossed type cable, connect it from the A terminal
to the B terminal, or from the B terminal to the A terminal (see
illustration below).
[B] Using the push-lock terminals
Make the connections to pins A, B, C (earth) of the CONTROL
terminal using a twisted-pair cable (sold separately). Then,
connect signal A to A, and signal B to B.
[C] SENSOR ALARM OUT terminals
When the unit internal video sensor send a trigger, it will be
output at the SENSOR ALARM OUT terminals. By connecting
indicator lamps switching circuits to theses connectors (Fig. 1),
an indication can be generated when the video sensors send a
trigger.
For example, the video sensor alarm indicator lamps could be
laid out on a factory floor plan to give accurate indication of
trigger location. The terminals are normally open (NO). A trigger
at the video sensor for one of the cameras, will switch the signal
to LOW.
Connect a 9-pin D-SUB cable (sold
separately) from the RS232C terminal on the
rear panel to the computer serial connector.
1
2
A
B
RS485
MONITOR
To terminal A
To terminal A
Straight-type cable
Cross-type cable
Straight type
1
6
Cross type
1
2
3
4
5
6
1
2
3
4
5
6
Not used
Not used
Not used
Not used
1
2
3
4
5
6
Not used
Not used
Not used
Not used
1
2
3
4
5
6
1
6
1
6
1
6
RS232C
C A B C AL C R1 R2 C SW C
Push in to insert cable
Twisted-pair cable
To A signal
To B signal
Ground
Fig. 1
Rating values for each connector (at 25˚C)
Maximum current : 25mA
Maximum voltage : 25V
Maximum power : 40mW
1K
RS232C
1 2 3 4 5 6 7 8 9 10 11 12 13 1415 16
C
C A B C AL C R1 R2 C SW C
A
B
RS485
ALARM IN
CONTROL
SENSOR ALARM
OUT
Computer
9-pin D-SUB cable
(sold separately)
External alarm sensors
(door bell, interphone, etc.)
Alarm input
terminal
Switching output
terminal
[A]
[B]
[C]
Common
Common
Common
L8FC5/US (MPX-CD162, MD162 GB) 2000. 8. 31
6