133
6. Specification
Mainframe
❖
Configuration:
Desktop
❖
Photosensitivity type:
OPC drum (
Φ
30)
❖
Original scanning:
One-dimensional solid scanning system through CCD
❖
Copy process:
Dry electrostatic transfer system
❖
Development:
Dry two-component magnetic brush development system
❖
Fusing:
Heating roll system
❖
Resolution:
600dpi
❖
Exposure glass:
Stationary original exposure type
❖
Original reference position:
Rear left corner
❖
Warm-up time:
Less than 45 seconds (20
°
C)
❖
Originals:
Sheet/book/objects
❖
Maximum original size:
A3L, 11"
×
17"L
❖
Copy paper size:
• Trays: A3L – A5L, 11"
×
17"L – 5
1
/
2
"
×
8
1
/
2
"L
• Bypass: A3L – A5L, 11"
×
17"L – 5
1
/
2
"
×
8
1
/
2
"L
• Bypass (non-standard size):
Vertical: 90 – 305mm, 3.6" – 12.0"
Horizontal: 148 – 432mm, 6.0" – 17.0"
• Duplex: A3L – A5L, 11"
×
17"L – 8
1
/
2
"
×
11"L
• LCT: A4K, 8
1
/