None of the components operate – Sundance Spas 850 User Manual
Page 44
check the message on the panel display; second, if you are still not satisfied
it is working properly, please follow the appropriate troubleshooting instruc-
tions.
PROBLEM PROCEDURE
NONE OF THE
Check the control panel lights.
COMPONENTS
1. If there are letters or symbols displayed on the
OPERATE (i.e.
screen, refer to the previous section to
pump, blower, light)
determine meaning and action required.
2. If nothing appears on the screen:
a. Check the household circuit breaker.
b. Contact you dealer or authorized service center.
PUMP DOES
Depress "JETS" sensor.
NOT OPERATE
1. If no sound is detected or if a "buzzing" sound is
BUT BLOWER
detected, turn off power to the hot tub and
AND LIGHT DO
contact your dealer or service center.
OPERATE
2. If motor operates but no water flows to jets:
a. Pump may not be properly primed. See
instructions below.
b. Contact dealer or authorized service center.
Pump Priming Instructions: Turn Hot Tub Off!
Remove filter and insert end of garden hose into left-side filter fitting. Seal-
off fitting opening around hose using a large, clean rag and hold in place.
Ask a helper to turn on maximum water flow through the garden hose.
After about 30 seconds, turn off water. Repeat process for right-side filter
fitting, then remove hose and rag. Reinstall filter as illustrated in section
11.1 (page 30-31) and activate pump 1 in high speed. Another method of
priming the hot tub’s pump(s) is as follows:
1.
Turn off the power to the hot tub.
2.
Remove the handle from the massage selector supplied by the pump
you are priming.
3.
Loosen the massage selector’s cap slightly (counterclockwise),
listening for the air to seep out.
4.
Tighten the cap finger-tight, replace the handle and turn the hot tub’s
power back on.
(Note: This method must be used for the single speed pump (pump #2) of
all Altamar, Cameo, Marin, and Optima models because pump #2 is not
connected to the filter.)