beautypg.com

Southbend P24C-CC User Manual

Page 41

background image

P

LATINUM

S

ERIES

S

ECTIONAL

R

ANGE

S

ERVICE

I

NSTALL AND

O

PERATIONS

M

ANUAL

1185836 R

EV

3 (07/06)

P

AGE

41

OF

80

Hot

BLOWER RUNS

INTERMITTENTLY

Check that the vents at each end of

the motor are not obstructed.

Check that the motor is not against

a wall.

Go to the junction box on the back

of the range and remove the cover.

Place a DVM or ammeter on the

black wire #1.

Check for excessive heat sources

behind the range.

Check for hot air leaks around the

motor pocket.

Cold

Check all wiring for loose

connections or breaks.

REMOVE THE MAIN POWER

SOURCE. UNPLUG OR

DISCONNECT CIRCUIT

BREAKER.

CAUTION! Be sure a DVM is

protected to 40 amps or greater.

Connect main power supply.

Turn on the oven Power Switch.

Observe that the amperage surges
and returns to the motor amperage

reading for high speed.

If the motor shuts off and there

is no excessive heat around the

blower motor it must be

replaced.

If the amperage surge remains at a

value greater than the rating

replace the motor.

Test oven.

Check that there are no air flow

obstructions around the range.

Check for excessive grease and

dust buildup on the motor.

Leave the blower turned on and

turn off the oven thermostat and

allow to cool.

If the blower starts up turn the oven

on and allow to reheat to 500

°F.

Blower

starts but