Notice, Installation of cable restraint – Southbend P24C-CC User Manual
Page 28
I
NSTALLATION
P
LATINUM
S
ERIES
S
ECTIONAL
R
ANGE
P
AGE
28
OF
80
I
NSTALL
& O
PERATIONS
M
ANUAL
1185836 R
EV
3
(07/06)
NOTICE
Adequate means must be provided to limit the movement of the appliance without depending on the connector and
the quick-disconnect device or its associated piping to limit the appliance movement.
The restraining means should be attached to a frame member on the back of the unit.
Figure 15
Installation of Cable Restraint
S
TEP
4: C
ONNECT
B
ATTERY
S
ECTIONS
If the range is part of a battery, and the battery was shipped partially disassembled, connect the battery sections using
the following procedure.
1. Remove valve panels from all sections. Mark them so that they can be returned to their respective section.
2. Position the center section of the battery and carefully level that unit. Use a long spirit level four ways; across
front top rail and the rear edge, and along each side edge.
3. If not already in place, attach pipe-union to front manifold of the battery. Screw it in far enough to be able to slide
the adjacent section into position.
4. Bring up adjacent section and level it using the same method and by using the center unit as reference. Match
front rails and rear edge. When a battery is set on a masonry base and legs are not used, shims may be used.
Special attention should be given to griddle ranges to allow proper drainage.
5. Bolt the frames of the sections together.
6. Connect the front manifolds using the pipe-union.
7. Attach the trim-strip between the section tops.
8. Install the continuous front-rail, if ordered.
9. Slide control knobs onto their shafts (to operate the sections during the installation procedure), but do not yet
reattach valve panels or front-panel trim pieces.