In order to maintain accuracy and precision with the oscil-
lating edge sander, periodically calibrate the angle gauge.
To calibrate the angle gauge, do these steps:
1. Loosen the angle adjustment lock handle.
2. Place the machinist's square on the table and press
it against the platen.
3. Adjust the platen until it is flush with the
machinist's square as in
Figure 37.
4. Tighten the angle adjustment lock handle.
5. Loosen the angle indicator pin screw, shown in
Figure 38, a 1/2 turn.
6. Align the angle indicator pin with the 90˚ mark and
tighten the angle indicator pin screw.
Calibrating Angle Gauge
Figure 37. Aligning table to platen.
Figure 38. Angle indicator pin screw.