Drainage – Sharp CV-P09LX User Manual
Page 31
ENGLISH
DRAINAGE
Prepare for drainage and drain out water within the unit in the following cases.
If the unit stops operating and the TIMER, OPERATION and MEGA COOL lamps are
blinking. (This indicates that the water tank inside the unit is full.)
1
Make sure to turn the unit off.
2
Turn the drainage nozzle to the OPEN
position.
3
Pull the stopcock out from the drainage
nozzle.
• When the stopcock is removed, a small amount of
water may be discharged from the drainage nozzle.
4
Insert the hose clamp into a standard
commercially available hose (5/8" inner
diameter, 7/8" outer diameter) and attach
the drain grommet to the hose.
5
Attach the hose to the drainage nozzle, and
secure it with the hose clamp.
• Prepare for draining, as drain water will come out
through the hose during operation.
6
Press the POWER button on the unit twice.
• The water will drain out through the drainage hose.
Maximum amount of water that may be drained
out is approximately 4
1
/
5
pints.
• The OPERATION, TIMER and MEGA COOL
lamps will be blinking.
7
When drainage water stops running out from the hose, turn the unit off by
pressing POWER button.
• This will take about one minute.
8
Remove the hose from the drainage nozzle, and replace the stopcock.
• Keep the hose clamp and drain grommet in case of re-used.
9
Turn the drainage nozzle to the CLOSE position.
Whenever the unit is moved (to prevent water within the unit from spilling).
When the unit is not used for a long time.
1
Carry out the above procedures from 1 to 5.
2
Press the POWER button on the unit.
• The water will drain out through the drainage hose.
Maximum amount of water that may be drained out is approximately 4
1
/
5
pints.
• The OPERATION lamps will light.
3
When drainage water stops running out from the hose, turn the unit off by
pressing POWER button.
• This will take about one minute.
4
Remove the hose from the drainage nozzle, and replace the stopcock.
• Keep the hose clamp and drain grommet in case of re-used.
5
Turn the drainage nozzle to the CLOSE position.
6
Remove the stopcock from the drainpipe nozzle, and completely drain any
water within the unit.
• Always prepare a receptacle to collect the water
before draining. Maximum amount of water that
may be drained out is approximately
2
/
5
pints.
7
Replace the stopcock to the drainpipe nozzle.
E-29
Stopcock
Drainpipe nozzle
Drainage
nozzle
Stopcock
Drain grommet
"OPEN" position
Hose clamp
Hose